|
Physio-Control
mechanical cpr device ![]() Mechanical Cpr Device, supplied by Physio-Control, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/lucas+3/3+chest+compression+device+lucas+mechanical/pmc12469095-75-24-31 Average 86 stars, based on 1 article reviews
mechanical cpr device - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Stryker
lucas 3 cpr device ![]() Lucas 3 Cpr Device, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/lucas+3/3+lucas/pm41095869-53-8-12 Average 86 stars, based on 1 article reviews
lucas 3 cpr device - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Jolife AB
automatic compression device lucas 3 ![]() Automatic Compression Device Lucas 3, supplied by Jolife AB, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/lucas+3/automatic+compression+device+lucas+3/pm37838142-98-1-7 Average 90 stars, based on 1 article reviews
automatic compression device lucas 3 - by Bioz Stars,
2026-09
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: PLOS One
Article Title: Right ventricular pressure–volume relations and effects of selective vena cava occlusion during cardiopulmonary resuscitation
doi: 10.1371/journal.pone.0333122
Figure Lengend Snippet: The x-axis displays the composite RVV (mL), and the y-axis shows the RVP (mmHg). The yellow loop, indicating spontaneous circulation, has a typical elliptical shape. The measurement loops at 2, 4, 12, 20, and 26 min after CPR initiation are shown in blue, green, pink, purple, and red, respectively. During CPR, the PV loops progressively take on a trapezoidal shape, indicating the loss of isovolumetric contraction and relaxation. This highlights the passive conduit role of the RV under external chest compressions. Unlike the elliptical loop during spontaneous circulation, these trapezoidal loops exhibit a limited volume range and show a more linear pressure increase during compression, with sharp drops during decompression. These patterns suggest modifications in RV filling and ejection mechanics during CPR. RV, right ventricular; PV, pressure–volume; CPR, cardiopulmonary resuscitation; RVV, right ventricular volume; RVP, right ventricular pressure.
Article Snippet: After 2 min of VF, chest compressions with a depth of 5 cm were performed at a rate of 100 compressions/min by using a
Techniques:
Journal: PLOS One
Article Title: Right ventricular pressure–volume relations and effects of selective vena cava occlusion during cardiopulmonary resuscitation
doi: 10.1371/journal.pone.0333122
Figure Lengend Snippet: No significant differences were observed in RV PV relationships during standard CPR without VCO, with SVCO, and with IVCO. (A) PV loops during standard CPR without VCO. The loops show compression-induced pressure fluctuations with reduced SV and a rightward shift as compared to those obtained during spontaneous circulation. (B) PV loops during CPR with SVCO. The overall shape and position of the loops are comparable to those observed during standard CPR without VCO, with no significant changes in SV or pressure development. (C) PV loops during CPR with IVCO. Similar to CPR with SVCO, the loops demonstrate no appreciable difference in RVP or RVV parameters as compared to standard CPR without VCO.
Article Snippet: After 2 min of VF, chest compressions with a depth of 5 cm were performed at a rate of 100 compressions/min by using a
Techniques: