grin lens diameter, length Search Results


90
Go Foton singlet grin lens 350 μm in diameter
Singlet Grin Lens 350 μm In Diameter, supplied by Go Foton, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/singlet+grin+lens+350+%CE%BCm+in+diameter/pm26799938-65-12-13
Average 90 stars, based on 1 article reviews
singlet grin lens 350 μm in diameter - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Go Foton gradient refractive index (grin) lens akca127
Gradient Refractive Index (Grin) Lens Akca127, supplied by Go Foton, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/either+a+1+8mm++akca127++akca130++akca135++or+0+5mm++akca170++camca130++diameter+gradient+refractive+index++grin++lens/pmc09065029-210-16-23
Average 90 stars, based on 1 article reviews
gradient refractive index (grin) lens akca127 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Inscopix Inc lens-electrode assembly grin lens diameter length
Lens Electrode Assembly Grin Lens Diameter Length, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/lens+electrode+assembly+grin+lens+diameter+length/pm35031630-265-11-19
Average 90 stars, based on 1 article reviews
lens-electrode assembly grin lens diameter length - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Inscopix Inc grin lens diameter; length
Grin Lens Diameter; Length, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/grin+lens+diameter++length/pm37176016-364-4-12
Average 90 stars, based on 1 article reviews
grin lens diameter; length - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Inscopix Inc proview integrated lens 1.0mm x 4.0mm with attached baseplate inscopix # 1050–004637
Proview Integrated Lens 1.0mm X 4.0mm With Attached Baseplate Inscopix # 1050–004637, supplied by Inscopix Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/grin+lens++1+0+diameter+++4+long/pmc12210276-571-12-13
Average 90 stars, based on 1 article reviews
proview integrated lens 1.0mm x 4.0mm with attached baseplate inscopix # 1050–004637 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thorlabs grin-lens coupled 50 um diameter, long optical fiber
Grin Lens Coupled 50 Um Diameter, Long Optical Fiber, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/grin+lens+coupled+50+um+diameter++long+optical+fiber/pmc03371152-36-46-49
Average 90 stars, based on 1 article reviews
grin-lens coupled 50 um diameter, long optical fiber - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
GRINTECH GmbH gradient-index (grin) lens attached to a 1mmsquare prism
Gradient Index (Grin) Lens Attached To A 1mmsquare Prism, supplied by GRINTECH GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/a+gradient+index++grin++lens+attached+to+a+1mmsquare+prism++total+length+approximately+4+67mm++optimised+for+920+nm+/pm35637903-308-11-21
Average 90 stars, based on 1 article reviews
gradient-index (grin) lens attached to a 1mmsquare prism - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Go Foton high refractive index (n-lasf31) right-angle micro prism and a diameter grin lens (0.98 pitch)
High Refractive Index (N Lasf31) Right Angle Micro Prism And A Diameter Grin Lens (0.98 Pitch), supplied by Go Foton, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/high+refractive+index++n+lasf31++right+angle+micro+prism+and+a+diameter+grin+lens++0+98+pitch+/pmc09241632-308-19-24
Average 90 stars, based on 1 article reviews
high refractive index (n-lasf31) right-angle micro prism and a diameter grin lens (0.98 pitch) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
GRINTECH GmbH compound doublet grin lenses 0.31 pitch grin micro-objective
Compound Doublet Grin Lenses 0.31 Pitch Grin Micro Objective, supplied by GRINTECH GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/grin+lens+diameter+length+0+4+pitch+0+50+numerical+aperture/pmc05289313-144-8-28
Average 90 stars, based on 1 article reviews
compound doublet grin lenses 0.31 pitch grin micro-objective - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Go Foton 500-μm diameter ilh uncoated grin lens
500 μm Diameter Ilh Uncoated Grin Lens, supplied by Go Foton, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/500+%CE%BCm+diameter+ilh+uncoated+grin+lens/10__1117_slash_1__jbo__17__2__021106-36-11-5
Average 90 stars, based on 1 article reviews
500-μm diameter ilh uncoated grin lens - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Edmund Optics a 1.8mm diameter gradient refractive index (grin) lens
( A ) To perform systematic manipulations of environmental geometry, we treated a square open field (75 x 75 cm) as an imagined 3 x 3 grid structure, blocking select partitions of the grid with 25 cm walls while mice freely navigated the open field. ( B ) To record large neuronal populations in CA1, mice were injected with a viral construct to express GCaMP6f in dorsal CA1 and implanted with <t>a</t> <t>gradient-refractive</t> index <t>(GRIN)</t> lens targeting CA1 (Methods). Spatial footprints and calcium transients were processed and binarized to create a firing rate vector for all recorded cells. ( C ) Following pre-exposure to the environment, we recorded a repeating sequence of randomly ordered geometries across days, starting and ending with the square environment for each sequence for up to three total repetitions (31 days). ( D ) Example rate maps of randomly selected cells registered on all days from a single sequence. The outline of aligned spatial footprints for each cell are shown (left) with rate maps for a target cell across deformations scaled to the maximum average firing across days (right). ( E ) The proportion of cells that were split-half reliable ( P <0.01) for each animal and the group average across all recorded sessions. We observed a significant increase in the proportion of cells identified as place cells across sessions (ANOVA: P <0.0001; F =37.5825). The group average is shown in the bold blue trace with shaded SEM, while individual animals are shown with thinner blue traces. ( F ) Average Bayesian position decoding error (cm) from all registered cells and animals across all recorded sessions. The dashed gray line indicates the estimated minimum decoding error from recent computational studies (10 cm) . We observed a significant decrease in decoding error across recorded sessions (ANOVA: P <0.0001; F =7.9845). ( G ) Population vector field maps show the direction and magnitude of displacement of the maximally correlated population vector in deformed environments relative to the same location in the square environment, while standard deviation of the vector across all cells is indicated in color. The vector field maps reveal the dynamics of remapping across all recorded neurons in each geometrically deformed environment compared to the square.
A 1.8mm Diameter Gradient Refractive Index (Grin) Lens, supplied by Edmund Optics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/a+1+8mm+diameter+gradient+refractive+index++grin++lens/bio_rxiv__2023__10__08__561112-97-8-14
Average 90 stars, based on 1 article reviews
a 1.8mm diameter gradient refractive index (grin) lens - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Edmund Optics grin lens .25 pitch, 0.55 na, 1.8mm diameter and 4.31mm in length
(A) A schematic illustration of AAV1 injection for targeted expression of GCaMP6f in bV1 excitatory neurons. A schematic illustration of a miniaturized fluorescent microscope (miniscope) used to image in vivo calcium signals in bV1 excitatory neurons in awake and freely behaving mice. The <t>GRIN</t> <t>lens,</t> implanted over bV1 at 2 weeks after an AAV1-Camk2a-GCaMP6f injection into bV1, is shown in grey. With the miniscope being fixed in place with a baseplate, reliable imaging of the same group of neurons over days can be repeatedly performed. Recording of neural and behavioral activity was performed during 5-10 minute sessions. (B) Representative maximum intensity Z-projection image showing recorded bV1 neurons from a combined recording session, scale bar = 50μm. (C) A spatial profile image shows extracted neurons and their contours (see white arrows) using the CNMF-E algorithm (see Materials and Methods for details) based on the concatenated video in (B), scale bar = 50μM. (D) Behavioral tracking data (black lines) of two representative wild type mice. The mice were introduced to a 35cm x 25cm behavioral arena under low lighting conditions (<20 lux), and miniscope and behavioral recordings were made. (E) Behavioral tracking data of two representative PV-Cre; ErbB4 fl/fl mice. (F) Calcium transient event data of two representative bV1 neurons from 2 different wild type mice (top, neuron 1; bottom, neuron 2). (G) Calcium transient event data of two neurons from two PV-Cre; ErbB4 fl/fl mice (top, neuron 1; bottom, neuron 2). (H) There is no significant difference in behavior (normalized distance; cm/min) between wild type and PV-Cre; ErbB4 fl/fl mice. (I) Average peak calcium event amplitudes, as determined by event amplitudes ( ; see Methods for details), for neurons from wild type mice (n = 360 cells) as compared to PV-Cre; ErbB4 fl/fl mice (n = 627 cells). (J) Average summed event amplitudes for neurons from wild type mice (n=260) as compared to PV-Cre; ErbB4 fl/fl mice (n=627) (*** p < 0.001; Student t tests). Data represent mean ± SEM.
Grin Lens .25 Pitch, 0.55 Na, 1.8mm Diameter And 4.31mm In Length, supplied by Edmund Optics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/grin+lens+diameter%2C+length/grin+lens++25+pitch++0+55+na++1+8mm+diameter+and+4+31mm+in+length/bio_rxiv__2020__03__16__994475-335-1-13
Average 90 stars, based on 1 article reviews
grin lens .25 pitch, 0.55 na, 1.8mm diameter and 4.31mm in length - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


( A ) To perform systematic manipulations of environmental geometry, we treated a square open field (75 x 75 cm) as an imagined 3 x 3 grid structure, blocking select partitions of the grid with 25 cm walls while mice freely navigated the open field. ( B ) To record large neuronal populations in CA1, mice were injected with a viral construct to express GCaMP6f in dorsal CA1 and implanted with a gradient-refractive index (GRIN) lens targeting CA1 (Methods). Spatial footprints and calcium transients were processed and binarized to create a firing rate vector for all recorded cells. ( C ) Following pre-exposure to the environment, we recorded a repeating sequence of randomly ordered geometries across days, starting and ending with the square environment for each sequence for up to three total repetitions (31 days). ( D ) Example rate maps of randomly selected cells registered on all days from a single sequence. The outline of aligned spatial footprints for each cell are shown (left) with rate maps for a target cell across deformations scaled to the maximum average firing across days (right). ( E ) The proportion of cells that were split-half reliable ( P <0.01) for each animal and the group average across all recorded sessions. We observed a significant increase in the proportion of cells identified as place cells across sessions (ANOVA: P <0.0001; F =37.5825). The group average is shown in the bold blue trace with shaded SEM, while individual animals are shown with thinner blue traces. ( F ) Average Bayesian position decoding error (cm) from all registered cells and animals across all recorded sessions. The dashed gray line indicates the estimated minimum decoding error from recent computational studies (10 cm) . We observed a significant decrease in decoding error across recorded sessions (ANOVA: P <0.0001; F =7.9845). ( G ) Population vector field maps show the direction and magnitude of displacement of the maximally correlated population vector in deformed environments relative to the same location in the square environment, while standard deviation of the vector across all cells is indicated in color. The vector field maps reveal the dynamics of remapping across all recorded neurons in each geometrically deformed environment compared to the square.

Journal: bioRxiv

Article Title: Identifying representational structure in CA1 to benchmark theoretical models of cognitive mapping

doi: 10.1101/2023.10.08.561112

Figure Lengend Snippet: ( A ) To perform systematic manipulations of environmental geometry, we treated a square open field (75 x 75 cm) as an imagined 3 x 3 grid structure, blocking select partitions of the grid with 25 cm walls while mice freely navigated the open field. ( B ) To record large neuronal populations in CA1, mice were injected with a viral construct to express GCaMP6f in dorsal CA1 and implanted with a gradient-refractive index (GRIN) lens targeting CA1 (Methods). Spatial footprints and calcium transients were processed and binarized to create a firing rate vector for all recorded cells. ( C ) Following pre-exposure to the environment, we recorded a repeating sequence of randomly ordered geometries across days, starting and ending with the square environment for each sequence for up to three total repetitions (31 days). ( D ) Example rate maps of randomly selected cells registered on all days from a single sequence. The outline of aligned spatial footprints for each cell are shown (left) with rate maps for a target cell across deformations scaled to the maximum average firing across days (right). ( E ) The proportion of cells that were split-half reliable ( P <0.01) for each animal and the group average across all recorded sessions. We observed a significant increase in the proportion of cells identified as place cells across sessions (ANOVA: P <0.0001; F =37.5825). The group average is shown in the bold blue trace with shaded SEM, while individual animals are shown with thinner blue traces. ( F ) Average Bayesian position decoding error (cm) from all registered cells and animals across all recorded sessions. The dashed gray line indicates the estimated minimum decoding error from recent computational studies (10 cm) . We observed a significant decrease in decoding error across recorded sessions (ANOVA: P <0.0001; F =7.9845). ( G ) Population vector field maps show the direction and magnitude of displacement of the maximally correlated population vector in deformed environments relative to the same location in the square environment, while standard deviation of the vector across all cells is indicated in color. The vector field maps reveal the dynamics of remapping across all recorded neurons in each geometrically deformed environment compared to the square.

Article Snippet: Between five to six weeks post-injection, a 1.8mm diameter gradient refractive index (GRIN) lens (Edmund Optics) was implanted above dorsal CA1 (Referenced to bregma: +/-1.45 mm ML, -1.95 mm AP; -1.37 mm DV from skull surface).

Techniques: Blocking Assay, Injection, Construct, Plasmid Preparation, Sequencing, Standard Deviation

( A ) Examples of spatial footprint (SFP) max-projections across a single geometric sequence in each animal following source extraction and across session image alignment (top), along with the respective animal’s estimated position using Deeplabcut (head center; bottom) . ( B ) Histological confirmation of GRIN lens implantation above dorsal CA1 (DAPI in red, GCaMP6f in green). Tissue damage following post-mortem lens extraction prevented histological confirmation of CA1 implant location in Mouse 6, but subsequent analyses confirmed this mouse was similar to the remaining subjects in the group (see below). ( C ) Top panel shows the total number of cells detected across all sessions in each animal (non-unique cells prior to across-session registration), and the bottom panel shows that the detected proportion of place cells did not differ across mice, confirming similar quality of spatial coding across subjects in CA1.

Journal: bioRxiv

Article Title: Identifying representational structure in CA1 to benchmark theoretical models of cognitive mapping

doi: 10.1101/2023.10.08.561112

Figure Lengend Snippet: ( A ) Examples of spatial footprint (SFP) max-projections across a single geometric sequence in each animal following source extraction and across session image alignment (top), along with the respective animal’s estimated position using Deeplabcut (head center; bottom) . ( B ) Histological confirmation of GRIN lens implantation above dorsal CA1 (DAPI in red, GCaMP6f in green). Tissue damage following post-mortem lens extraction prevented histological confirmation of CA1 implant location in Mouse 6, but subsequent analyses confirmed this mouse was similar to the remaining subjects in the group (see below). ( C ) Top panel shows the total number of cells detected across all sessions in each animal (non-unique cells prior to across-session registration), and the bottom panel shows that the detected proportion of place cells did not differ across mice, confirming similar quality of spatial coding across subjects in CA1.

Article Snippet: Between five to six weeks post-injection, a 1.8mm diameter gradient refractive index (GRIN) lens (Edmund Optics) was implanted above dorsal CA1 (Referenced to bregma: +/-1.45 mm ML, -1.95 mm AP; -1.37 mm DV from skull surface).

Techniques: Sequencing, Extraction

(A) A schematic illustration of AAV1 injection for targeted expression of GCaMP6f in bV1 excitatory neurons. A schematic illustration of a miniaturized fluorescent microscope (miniscope) used to image in vivo calcium signals in bV1 excitatory neurons in awake and freely behaving mice. The GRIN lens, implanted over bV1 at 2 weeks after an AAV1-Camk2a-GCaMP6f injection into bV1, is shown in grey. With the miniscope being fixed in place with a baseplate, reliable imaging of the same group of neurons over days can be repeatedly performed. Recording of neural and behavioral activity was performed during 5-10 minute sessions. (B) Representative maximum intensity Z-projection image showing recorded bV1 neurons from a combined recording session, scale bar = 50μm. (C) A spatial profile image shows extracted neurons and their contours (see white arrows) using the CNMF-E algorithm (see Materials and Methods for details) based on the concatenated video in (B), scale bar = 50μM. (D) Behavioral tracking data (black lines) of two representative wild type mice. The mice were introduced to a 35cm x 25cm behavioral arena under low lighting conditions (<20 lux), and miniscope and behavioral recordings were made. (E) Behavioral tracking data of two representative PV-Cre; ErbB4 fl/fl mice. (F) Calcium transient event data of two representative bV1 neurons from 2 different wild type mice (top, neuron 1; bottom, neuron 2). (G) Calcium transient event data of two neurons from two PV-Cre; ErbB4 fl/fl mice (top, neuron 1; bottom, neuron 2). (H) There is no significant difference in behavior (normalized distance; cm/min) between wild type and PV-Cre; ErbB4 fl/fl mice. (I) Average peak calcium event amplitudes, as determined by event amplitudes ( ; see Methods for details), for neurons from wild type mice (n = 360 cells) as compared to PV-Cre; ErbB4 fl/fl mice (n = 627 cells). (J) Average summed event amplitudes for neurons from wild type mice (n=260) as compared to PV-Cre; ErbB4 fl/fl mice (n=627) (*** p < 0.001; Student t tests). Data represent mean ± SEM.

Journal: bioRxiv

Article Title: Subanesthetic ketamine reactivates adult cortical plasticity to restore vision from amblyopia

doi: 10.1101/2020.03.16.994475

Figure Lengend Snippet: (A) A schematic illustration of AAV1 injection for targeted expression of GCaMP6f in bV1 excitatory neurons. A schematic illustration of a miniaturized fluorescent microscope (miniscope) used to image in vivo calcium signals in bV1 excitatory neurons in awake and freely behaving mice. The GRIN lens, implanted over bV1 at 2 weeks after an AAV1-Camk2a-GCaMP6f injection into bV1, is shown in grey. With the miniscope being fixed in place with a baseplate, reliable imaging of the same group of neurons over days can be repeatedly performed. Recording of neural and behavioral activity was performed during 5-10 minute sessions. (B) Representative maximum intensity Z-projection image showing recorded bV1 neurons from a combined recording session, scale bar = 50μm. (C) A spatial profile image shows extracted neurons and their contours (see white arrows) using the CNMF-E algorithm (see Materials and Methods for details) based on the concatenated video in (B), scale bar = 50μM. (D) Behavioral tracking data (black lines) of two representative wild type mice. The mice were introduced to a 35cm x 25cm behavioral arena under low lighting conditions (<20 lux), and miniscope and behavioral recordings were made. (E) Behavioral tracking data of two representative PV-Cre; ErbB4 fl/fl mice. (F) Calcium transient event data of two representative bV1 neurons from 2 different wild type mice (top, neuron 1; bottom, neuron 2). (G) Calcium transient event data of two neurons from two PV-Cre; ErbB4 fl/fl mice (top, neuron 1; bottom, neuron 2). (H) There is no significant difference in behavior (normalized distance; cm/min) between wild type and PV-Cre; ErbB4 fl/fl mice. (I) Average peak calcium event amplitudes, as determined by event amplitudes ( ; see Methods for details), for neurons from wild type mice (n = 360 cells) as compared to PV-Cre; ErbB4 fl/fl mice (n = 627 cells). (J) Average summed event amplitudes for neurons from wild type mice (n=260) as compared to PV-Cre; ErbB4 fl/fl mice (n=627) (*** p < 0.001; Student t tests). Data represent mean ± SEM.

Article Snippet: The GRIN lens (.25 pitch, 0.55 NA, 1.8mm diameter and 4.31mm in length; Edmund Optics) was slowly lowered with a stereotaxic arm onto the surface of the cortex for bV1.

Techniques: Injection, Expressing, Microscopy, In Vivo, Imaging, Activity Assay

(A) The left image panel shows a coronal brain section from an experiment mouse with the dashed lines indicating the boundaries of a GRIN lens implant. The DAPI staining is blue, and GCaMP6f expression is green. The right panel show an enlarged region of V1 beneath the lens. Overall normal-looking structures and GCaMP6f expression in visual cortex provide support for the imaging of healthy V1 excitatory cells. (B) The upper traces show the temporal trace of calcium signal activity from an example cell from miniscope-based GCaMP6 imaging and the corresponding deconvolved trace (red) is used for inferring spiking activity. Lower traces show the expanded segment of both traces indicated in the black box above. See Methods for more details. We use deconvolved traces for downstream analysis and apply a threshold of 10% of the maxima of peak responses in these traces across all of the sessions to identify effective calcium events. Two-photon calcium imaging data are similarly processed.

Journal: bioRxiv

Article Title: Subanesthetic ketamine reactivates adult cortical plasticity to restore vision from amblyopia

doi: 10.1101/2020.03.16.994475

Figure Lengend Snippet: (A) The left image panel shows a coronal brain section from an experiment mouse with the dashed lines indicating the boundaries of a GRIN lens implant. The DAPI staining is blue, and GCaMP6f expression is green. The right panel show an enlarged region of V1 beneath the lens. Overall normal-looking structures and GCaMP6f expression in visual cortex provide support for the imaging of healthy V1 excitatory cells. (B) The upper traces show the temporal trace of calcium signal activity from an example cell from miniscope-based GCaMP6 imaging and the corresponding deconvolved trace (red) is used for inferring spiking activity. Lower traces show the expanded segment of both traces indicated in the black box above. See Methods for more details. We use deconvolved traces for downstream analysis and apply a threshold of 10% of the maxima of peak responses in these traces across all of the sessions to identify effective calcium events. Two-photon calcium imaging data are similarly processed.

Article Snippet: The GRIN lens (.25 pitch, 0.55 NA, 1.8mm diameter and 4.31mm in length; Edmund Optics) was slowly lowered with a stereotaxic arm onto the surface of the cortex for bV1.

Techniques: Staining, Expressing, Imaging, Activity Assay