gene test kits Search Results


90
Hangzhou Zheda Dixun Biological Gene Engineering allergen-specific ige detection kit (immunoblotting method)
Allergen Specific Ige Detection Kit (Immunoblotting Method), supplied by Hangzhou Zheda Dixun Biological Gene Engineering, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/hdm+component+specific+ige+and+igg4+antibodies+test+kits/pmc11617527-91-17-24
Average 90 stars, based on 1 article reviews
allergen-specific ige detection kit (immunoblotting method) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Yaneng Bioscience Co Ltd gene test kits
Gene Test Kits, supplied by Yaneng Bioscience Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/gene+test+kits/pm36066284-38-9-14
Average 90 stars, based on 1 article reviews
gene test kits - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DaAn Gene cfda-certified test kits
Cfda Certified Test Kits, supplied by DaAn Gene, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/cfda+certified+test+kits/pmc07782353-95-15-18
Average 90 stars, based on 1 article reviews
cfda-certified test kits - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DaAn Gene hiv test kits
Evaluation of the CRISPR-based latera-flow strip for <t>HIV-1</t> RNA detection. A-B CRISPR-based fluorescence assay for detecting HIV-1 RNA concentration at 1 h. C-D CRISPR-based latera-flow strip assay for HIV-1 RNA detection and the band intensities. E–F Distribution of Ct values <t>of</t> <t>RT-qPCR</t> method and amplification curve of HIV-1 RNA at different concentrations. G Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-PCR (The uncropped result is shown in Supplementary Figure S ). H Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-RAA (The uncropped result is shown in Supplementary Figure S ). NC: Negative control,
Hiv Test Kits, supplied by DaAn Gene, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/hiv+test+kits/pmc10518925-138-1-16
Average 90 stars, based on 1 article reviews
hiv test kits - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Eurofins pcr test kits for the type i growth hormone gene
Evaluation of the CRISPR-based latera-flow strip for <t>HIV-1</t> RNA detection. A-B CRISPR-based fluorescence assay for detecting HIV-1 RNA concentration at 1 h. C-D CRISPR-based latera-flow strip assay for HIV-1 RNA detection and the band intensities. E–F Distribution of Ct values <t>of</t> <t>RT-qPCR</t> method and amplification curve of HIV-1 RNA at different concentrations. G Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-PCR (The uncropped result is shown in Supplementary Figure S ). H Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-RAA (The uncropped result is shown in Supplementary Figure S ). NC: Negative control,
Pcr Test Kits For The Type I Growth Hormone Gene, supplied by Eurofins, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/pcr+test+kits+for+the+type+i+growth+hormone+gene/pm35150203-597-80-85
Average 90 stars, based on 1 article reviews
pcr test kits for the type i growth hormone gene - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
23andMe at-home kits that test for three breast cancer gene mutations
Top influencers among tweets identified during the study period
At Home Kits That Test For Three Breast Cancer Gene Mutations, supplied by 23andMe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gene+test+kits/at+home+kits+that+test+for+three+breast+cancer+gene+mutations/pmc06993995-3-24-16
Average 90 stars, based on 1 article reviews
at-home kits that test for three breast cancer gene mutations - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Evaluation of the CRISPR-based latera-flow strip for HIV-1 RNA detection. A-B CRISPR-based fluorescence assay for detecting HIV-1 RNA concentration at 1 h. C-D CRISPR-based latera-flow strip assay for HIV-1 RNA detection and the band intensities. E–F Distribution of Ct values of RT-qPCR method and amplification curve of HIV-1 RNA at different concentrations. G Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-PCR (The uncropped result is shown in Supplementary Figure S ). H Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-RAA (The uncropped result is shown in Supplementary Figure S ). NC: Negative control,

Journal: BMC Infectious Diseases

Article Title: Highly sensitive and rapid point-of-care testing for HIV-1 infection based on CRISPR-Cas13a system

doi: 10.1186/s12879-023-08492-6

Figure Lengend Snippet: Evaluation of the CRISPR-based latera-flow strip for HIV-1 RNA detection. A-B CRISPR-based fluorescence assay for detecting HIV-1 RNA concentration at 1 h. C-D CRISPR-based latera-flow strip assay for HIV-1 RNA detection and the band intensities. E–F Distribution of Ct values of RT-qPCR method and amplification curve of HIV-1 RNA at different concentrations. G Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-PCR (The uncropped result is shown in Supplementary Figure S ). H Agarose gel electrophoresis of HIV-1 RNA with different concentrations after RT-RAA (The uncropped result is shown in Supplementary Figure S ). NC: Negative control, "****" means P < 0.0001, "***", "**" means P < 0.005, and "ns" means no significant difference. All experiments were carried out in triplicate for data analysis

Article Snippet: The HIV test kits, RT-qPCR HIV-1 reaction kit, used for clinical samples were purchased from the DaAn Gene Co., Ltd. of Sun Yat-sen University.

Techniques: CRISPR, Stripping Membranes, RNA Detection, Fluorescence, Concentration Assay, Quantitative RT-PCR, Amplification, Agarose Gel Electrophoresis, Reverse Transcription Polymerase Chain Reaction, Negative Control

RT-RAA-CRISPR-Cas13a detected HIV-1 in 158 plasma clinical samples. Positive HIV-1 clinical samples were classified according to their C t values from RT-qPCR and the total number of clinical samples in each Ct classification is shown. Representative lateral-flow strip and fluorescence detection of each C t bin as well as HIV-1 negative samples are shown. The full dataset is shown in Supplementary Fig. . For lateral-flow strip readings, the disappearance of the colored test strip, often combined with the appearance of the colored control strip, indicates a positive HIV-1 result. For fluorescence readings, we set a threshold for the signal-to-noise (S/N) ratio of fluorescence intensity (blue line) (noise is the fluorescence intensity from negative samples performed in parallel with water as input), and positive results are 3. Bottom row shows the number of false negative samples; false negative result rates are shown for each C t bin and for the two RT-RAA-CRISPR-Cas13a readout modes

Journal: BMC Infectious Diseases

Article Title: Highly sensitive and rapid point-of-care testing for HIV-1 infection based on CRISPR-Cas13a system

doi: 10.1186/s12879-023-08492-6

Figure Lengend Snippet: RT-RAA-CRISPR-Cas13a detected HIV-1 in 158 plasma clinical samples. Positive HIV-1 clinical samples were classified according to their C t values from RT-qPCR and the total number of clinical samples in each Ct classification is shown. Representative lateral-flow strip and fluorescence detection of each C t bin as well as HIV-1 negative samples are shown. The full dataset is shown in Supplementary Fig. . For lateral-flow strip readings, the disappearance of the colored test strip, often combined with the appearance of the colored control strip, indicates a positive HIV-1 result. For fluorescence readings, we set a threshold for the signal-to-noise (S/N) ratio of fluorescence intensity (blue line) (noise is the fluorescence intensity from negative samples performed in parallel with water as input), and positive results are 3. Bottom row shows the number of false negative samples; false negative result rates are shown for each C t bin and for the two RT-RAA-CRISPR-Cas13a readout modes

Article Snippet: The HIV test kits, RT-qPCR HIV-1 reaction kit, used for clinical samples were purchased from the DaAn Gene Co., Ltd. of Sun Yat-sen University.

Techniques: CRISPR, Clinical Proteomics, Quantitative RT-PCR, Stripping Membranes, Fluorescence, Control

Top influencers among tweets identified during the study period

Journal: JAMIA Open

Article Title: The FDA authorization of direct-to-consumer genetic testing for three BRCA1/2 pathogenic variants: a twitter analysis of the public’s response

doi: 10.1093/jamiaopen/ooz037

Figure Lengend Snippet: Top influencers among tweets identified during the study period

Article Snippet: @cnni , CNN International , UK , 148377 , 7610479 , 3/7 , Genetic testing company 23andMe has been give federal approval to sell at-home kits that test for three breast cancer gene mutations https://t.co/vtyVgfsXx6 https://t.co/dow9Oqy54q.

Techniques:

Qualitative findings and exemplar tweets

Journal: JAMIA Open

Article Title: The FDA authorization of direct-to-consumer genetic testing for three BRCA1/2 pathogenic variants: a twitter analysis of the public’s response

doi: 10.1093/jamiaopen/ooz037

Figure Lengend Snippet: Qualitative findings and exemplar tweets

Article Snippet: @cnni , CNN International , UK , 148377 , 7610479 , 3/7 , Genetic testing company 23andMe has been give federal approval to sell at-home kits that test for three breast cancer gene mutations https://t.co/vtyVgfsXx6 https://t.co/dow9Oqy54q.

Techniques: Mutagenesis