fully threaded cannulated screw Search Results


90
Axomed GmbH retrograde transpubic titanium screw
Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral <t>retrograde</t> <t>transpubic</t> screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.
Retrograde Transpubic Titanium Screw, supplied by Axomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fully+threaded+cannulated+screw/7+3+%C3%97+cannulated+fully+threaded+si+screws/pmc08585079-47-18-22
Average 90 stars, based on 1 article reviews
retrograde transpubic titanium screw - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
NuVasive Inc titanium screws and plates
Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral <t>retrograde</t> <t>transpubic</t> screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.
Titanium Screws And Plates, supplied by NuVasive Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fully+threaded+cannulated+screw/fully+threaded+titanium+cannulated+%C3%97+modular+pedicle+screw+without+tulip+precept/pmc08908052-65-13-14
Average 90 stars, based on 1 article reviews
titanium screws and plates - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DePuy Synthes fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws
Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral <t>retrograde</t> <t>transpubic</t> screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.
Fully Threaded Self Tapping Stainless Steel Cannulated Sacro Iliac (Si) Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fully+threaded+cannulated+screw/fully+threaded+self+tapping+stainless+steel+cannulated+sacro+iliac++si++screws/pmc10229737-54-3-11
Average 90 stars, based on 1 article reviews
fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
DePuy Synthes polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip
Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral <t>retrograde</t> <t>transpubic</t> screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.
Polyaxial, Dual Lead Threaded, And Fully Cannulated Screw With Three Fenestrations In The Distal Tip, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fully+threaded+cannulated+screw/polyaxial++dual+lead+threaded++and+fully+cannulated+screw+with+three+fenestrations+in+the+distal+tip/pmc10971248-51-11-23
Average 90 stars, based on 1 article reviews
polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral retrograde transpubic screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.

Journal: Journal of Clinical Medicine

Article Title: Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation

doi: 10.3390/jcm10215049

Figure Lengend Snippet: Anterior view of two specimens prepared for biomechanical testing with simulated straddle fracture of the pelvis, fixed with either an anterior plate (left, ( A ), group 1) or two bilateral retrograde transpubic screws (right, ( B ), group 2) and equipped with optical markers for motion tracking.

Article Snippet: Following their reduction, the fragments of the superior rami were fixated with one fully-threaded 4.5 × 70 mm retrograde transpubic titanium screw (Axomed GmbH, Freiburg, Germany) on each side ( B) according to the technical guidelines prescribed by Gänsslen et al. [ ].

Techniques:

Axial stiffness, cycles to failure and failure load in the study groups, presented in terms of mean value and standard deviation.

Journal: Journal of Clinical Medicine

Article Title: Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation

doi: 10.3390/jcm10215049

Figure Lengend Snippet: Axial stiffness, cycles to failure and failure load in the study groups, presented in terms of mean value and standard deviation.

Article Snippet: Following their reduction, the fragments of the superior rami were fixated with one fully-threaded 4.5 × 70 mm retrograde transpubic titanium screw (Axomed GmbH, Freiburg, Germany) on each side ( B) according to the technical guidelines prescribed by Gänsslen et al. [ ].

Techniques:

Fracture displacement in the study groups after 1000, 2000, 3000, 4000 and 5000 cycles, presented in terms of median and interquartile range (the latter in brackets).

Journal: Journal of Clinical Medicine

Article Title: Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation

doi: 10.3390/jcm10215049

Figure Lengend Snippet: Fracture displacement in the study groups after 1000, 2000, 3000, 4000 and 5000 cycles, presented in terms of median and interquartile range (the latter in brackets).

Article Snippet: Following their reduction, the fragments of the superior rami were fixated with one fully-threaded 4.5 × 70 mm retrograde transpubic titanium screw (Axomed GmbH, Freiburg, Germany) on each side ( B) according to the technical guidelines prescribed by Gänsslen et al. [ ].

Techniques:

Relative flexural rotations in the study groups after 1000, 2000, 3000, 4000 and 5000 cycles, presented in terms of median and interquartile range (the latter in brackets).

Journal: Journal of Clinical Medicine

Article Title: Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation

doi: 10.3390/jcm10215049

Figure Lengend Snippet: Relative flexural rotations in the study groups after 1000, 2000, 3000, 4000 and 5000 cycles, presented in terms of median and interquartile range (the latter in brackets).

Article Snippet: Following their reduction, the fragments of the superior rami were fixated with one fully-threaded 4.5 × 70 mm retrograde transpubic titanium screw (Axomed GmbH, Freiburg, Germany) on each side ( B) according to the technical guidelines prescribed by Gänsslen et al. [ ].

Techniques:

Predrilling of the retrograde transpubic screws was performed with a 3.5 mm drill bit. An aiming template made of polymethylmetharcylate was used to achieve the best possible instrumentation reproducibility.

Journal: Journal of Clinical Medicine

Article Title: Is Anterior Plating Superior to the Bilateral Use of Retrograde Transpubic Screws for Treatment of Straddle Pelvic Ring Fractures? A Biomechanical Investigation

doi: 10.3390/jcm10215049

Figure Lengend Snippet: Predrilling of the retrograde transpubic screws was performed with a 3.5 mm drill bit. An aiming template made of polymethylmetharcylate was used to achieve the best possible instrumentation reproducibility.

Article Snippet: Following their reduction, the fragments of the superior rami were fixated with one fully-threaded 4.5 × 70 mm retrograde transpubic titanium screw (Axomed GmbH, Freiburg, Germany) on each side ( B) according to the technical guidelines prescribed by Gänsslen et al. [ ].

Techniques: