custom-built ecg amplifier Search Results


90
Vibraspec Inc ecg amplifier vibraspec
A, heart weight (wet) of CSQ-overexpressing mice (CSQ) and non-transgenic littermates (Control) increased at a different rate with age ( P < 0.001, ANOVA). B and C, left ventricular (LV) end-diastolic diameter (B) and fractional shortening (C) were measured as a function of age by sequential <t>echocardiography.</t> D, Kaplan-Meier plot of survival probability. Survival decreased significantly after about 3 months. In B and C, values are means ±s.e.m.* P < 0.05 vs. control; n, number of animals studied.
Ecg Amplifier Vibraspec, supplied by Vibraspec Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/ecg+amplifier+vibraspec/pmc02269956-66-1-4
Average 90 stars, based on 1 article reviews
ecg amplifier vibraspec - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vibraspec Inc ecg amplifier
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Ecg Amplifier, supplied by Vibraspec Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/ecg+amplifier/pmc02269956-66-2-4
Average 90 stars, based on 1 article reviews
ecg amplifier - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vibraspec Inc ecg amplifier vibraspec bear island me 04662
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Ecg Amplifier Vibraspec Bear Island Me 04662, supplied by Vibraspec Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/ecg+amplifier+vibraspec+bear+island+me+04662/10__1074_slash_jbc__m006745200-66-23-26
Average 90 stars, based on 1 article reviews
ecg amplifier vibraspec bear island me 04662 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
iWorx Systems Inc ecg amplifier ix-ra-834
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Ecg Amplifier Ix Ra 834, supplied by iWorx Systems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/ix+ra+834/pmc06444638-54-21-33
Average 90 stars, based on 1 article reviews
ecg amplifier ix-ra-834 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
honeywell international pressure transducer 24pcefa6 d
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Pressure Transducer 24pcefa6 D, supplied by honeywell international, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/pressure+transducer+24pcefa6+d/pmc06792269-139-14-18
Average 90 stars, based on 1 article reviews
pressure transducer 24pcefa6 d - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Cambridge Electronic Design ced micro1401 a–d interface
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Ced Micro1401 A–D Interface, supplied by Cambridge Electronic Design, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/micro+1401/pmc03097374-101-36-41
Average 90 stars, based on 1 article reviews
ced micro1401 a–d interface - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
BIOPAC physiological recording system mp150
Comparison of body weight, heart weight, <t> echocardiography </t> and <t> ECG </t> findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)
Physiological Recording System Mp150, supplied by BIOPAC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/custom-built+ecg+amplifier/mp150/pmc06154312-45-10-14
Average 90 stars, based on 1 article reviews
physiological recording system mp150 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


A, heart weight (wet) of CSQ-overexpressing mice (CSQ) and non-transgenic littermates (Control) increased at a different rate with age ( P < 0.001, ANOVA). B and C, left ventricular (LV) end-diastolic diameter (B) and fractional shortening (C) were measured as a function of age by sequential echocardiography. D, Kaplan-Meier plot of survival probability. Survival decreased significantly after about 3 months. In B and C, values are means ±s.e.m.* P < 0.05 vs. control; n, number of animals studied.

Journal:

Article Title: Remodelling of ionic currents in hypertrophied and failing hearts of transgenic mice overexpressing calsequestrin

doi: 10.1111/j.1469-7793.2000.t01-1-00483.x

Figure Lengend Snippet: A, heart weight (wet) of CSQ-overexpressing mice (CSQ) and non-transgenic littermates (Control) increased at a different rate with age ( P < 0.001, ANOVA). B and C, left ventricular (LV) end-diastolic diameter (B) and fractional shortening (C) were measured as a function of age by sequential echocardiography. D, Kaplan-Meier plot of survival probability. Survival decreased significantly after about 3 months. In B and C, values are means ±s.e.m.* P < 0.05 vs. control; n, number of animals studied.

Article Snippet: A custom-built ECG amplifier (Vibraspec, Bear Island, ME, USA) with a high-frequency filter of 100 Hz and 10000-fold gain was used to record six bipolar limb leads in standard fashion.

Techniques: Transgenic Assay, Control

Comparison of body weight, heart weight,  echocardiography  and  ECG  findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)

Journal:

Article Title: Remodelling of ionic currents in hypertrophied and failing hearts of transgenic mice overexpressing calsequestrin

doi: 10.1111/j.1469-7793.2000.t01-1-00483.x

Figure Lengend Snippet: Comparison of body weight, heart weight, echocardiography and ECG findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)

Article Snippet: A custom-built ECG amplifier (Vibraspec, Bear Island, ME, USA) with a high-frequency filter of 100 Hz and 10000-fold gain was used to record six bipolar limb leads in standard fashion.

Techniques: Comparison, Transgenic Assay, Control

A, representative ECG tracings (lead II) from control and transgenic mice overexpressing CSQ (aged 139 and 134 days, respectively). The various parameters of the ECG are indicated; P represents atrial depolarization (P-wave) and T the ventricular repolarization (T-wave). A wider QRS complex and a prolonged Q-T interval were consistently encountered in CSQ mice. B, approximately 30 % of CSQ mice had an alternating pattern of the T-wave (lead II, T-wave alternans, top panel) in all age groups examined. A long P-R interval (P-R > 45 ms), higher degrees of atrioventricular block (AVB, lead I, middle and bottom panels) or QRS morphologies suggestive of conduction blocks (middle panel) were only present in CSQ mice older than 60 days. C, the cardiac action potential was significantly prolonged in ventricular cells from CSQ mice, both at the 50 % and the 90 % repolarization level (APD50 and APD90, respectively). Resting membrane potential (Vm) and overshoot potential were not significantly different. Mean values are given above each bar; error bars are s.e.m. Control: 19 myocytes from 3 hearts; mean age, 109 days. CSQ: 13 myocytes from 4 hearts; mean age, 139 days. *** P < 0.001 vs. control.

Journal:

Article Title: Remodelling of ionic currents in hypertrophied and failing hearts of transgenic mice overexpressing calsequestrin

doi: 10.1111/j.1469-7793.2000.t01-1-00483.x

Figure Lengend Snippet: A, representative ECG tracings (lead II) from control and transgenic mice overexpressing CSQ (aged 139 and 134 days, respectively). The various parameters of the ECG are indicated; P represents atrial depolarization (P-wave) and T the ventricular repolarization (T-wave). A wider QRS complex and a prolonged Q-T interval were consistently encountered in CSQ mice. B, approximately 30 % of CSQ mice had an alternating pattern of the T-wave (lead II, T-wave alternans, top panel) in all age groups examined. A long P-R interval (P-R > 45 ms), higher degrees of atrioventricular block (AVB, lead I, middle and bottom panels) or QRS morphologies suggestive of conduction blocks (middle panel) were only present in CSQ mice older than 60 days. C, the cardiac action potential was significantly prolonged in ventricular cells from CSQ mice, both at the 50 % and the 90 % repolarization level (APD50 and APD90, respectively). Resting membrane potential (Vm) and overshoot potential were not significantly different. Mean values are given above each bar; error bars are s.e.m. Control: 19 myocytes from 3 hearts; mean age, 109 days. CSQ: 13 myocytes from 4 hearts; mean age, 139 days. *** P < 0.001 vs. control.

Article Snippet: A custom-built ECG amplifier (Vibraspec, Bear Island, ME, USA) with a high-frequency filter of 100 Hz and 10000-fold gain was used to record six bipolar limb leads in standard fashion.

Techniques: Control, Transgenic Assay, Blocking Assay, Membrane

Comparison of body weight, heart weight,  echocardiography  and  ECG  findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)

Journal:

Article Title: Remodelling of ionic currents in hypertrophied and failing hearts of transgenic mice overexpressing calsequestrin

doi: 10.1111/j.1469-7793.2000.t01-1-00483.x

Figure Lengend Snippet: Comparison of body weight, heart weight, echocardiography and ECG findings for transgenic (CSQ) mice and age-matched non-transgenic littermates (control)

Article Snippet: A custom-built ECG amplifier (Vibraspec, Bear Island, ME, USA) with a high-frequency filter of 100 Hz and 10000-fold gain was used to record six bipolar limb leads in standard fashion.

Techniques: Transgenic Assay

A, representative ECG tracings (lead II) from control and transgenic mice overexpressing CSQ (aged 139 and 134 days, respectively). The various parameters of the ECG are indicated; P represents atrial depolarization (P-wave) and T the ventricular repolarization (T-wave). A wider QRS complex and a prolonged Q-T interval were consistently encountered in CSQ mice. B, approximately 30 % of CSQ mice had an alternating pattern of the T-wave (lead II, T-wave alternans, top panel) in all age groups examined. A long P-R interval (P-R > 45 ms), higher degrees of atrioventricular block (AVB, lead I, middle and bottom panels) or QRS morphologies suggestive of conduction blocks (middle panel) were only present in CSQ mice older than 60 days. C, the cardiac action potential was significantly prolonged in ventricular cells from CSQ mice, both at the 50 % and the 90 % repolarization level (APD50 and APD90, respectively). Resting membrane potential (Vm) and overshoot potential were not significantly different. Mean values are given above each bar; error bars are s.e.m. Control: 19 myocytes from 3 hearts; mean age, 109 days. CSQ: 13 myocytes from 4 hearts; mean age, 139 days. *** P < 0.001 vs. control.

Journal:

Article Title: Remodelling of ionic currents in hypertrophied and failing hearts of transgenic mice overexpressing calsequestrin

doi: 10.1111/j.1469-7793.2000.t01-1-00483.x

Figure Lengend Snippet: A, representative ECG tracings (lead II) from control and transgenic mice overexpressing CSQ (aged 139 and 134 days, respectively). The various parameters of the ECG are indicated; P represents atrial depolarization (P-wave) and T the ventricular repolarization (T-wave). A wider QRS complex and a prolonged Q-T interval were consistently encountered in CSQ mice. B, approximately 30 % of CSQ mice had an alternating pattern of the T-wave (lead II, T-wave alternans, top panel) in all age groups examined. A long P-R interval (P-R > 45 ms), higher degrees of atrioventricular block (AVB, lead I, middle and bottom panels) or QRS morphologies suggestive of conduction blocks (middle panel) were only present in CSQ mice older than 60 days. C, the cardiac action potential was significantly prolonged in ventricular cells from CSQ mice, both at the 50 % and the 90 % repolarization level (APD50 and APD90, respectively). Resting membrane potential (Vm) and overshoot potential were not significantly different. Mean values are given above each bar; error bars are s.e.m. Control: 19 myocytes from 3 hearts; mean age, 109 days. CSQ: 13 myocytes from 4 hearts; mean age, 139 days. *** P < 0.001 vs. control.

Article Snippet: A custom-built ECG amplifier (Vibraspec, Bear Island, ME, USA) with a high-frequency filter of 100 Hz and 10000-fold gain was used to record six bipolar limb leads in standard fashion.

Techniques: Transgenic Assay, Blocking Assay