covid-19 detection Search Results


90
Ramco Laboratories Inc innovation attendance tracking with facial recognition and thermal scanning detects covid-19
Innovation Attendance Tracking With Facial Recognition And Thermal Scanning Detects Covid 19, supplied by Ramco Laboratories Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/innovation+attendance+tracking+with+facial+recognition+and+thermal+scanning+detects+covid+19/pmc07337876-291-0-0
Average 90 stars, based on 1 article reviews
innovation attendance tracking with facial recognition and thermal scanning detects covid-19 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Atila Biosystems iamp covid-19 detection kit
Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.
Iamp Covid 19 Detection Kit, supplied by Atila Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/iamp+covid+19+detection+kit/pmc07823986-85-4-0
Average 90 stars, based on 1 article reviews
iamp covid-19 detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SEASUN BIOMATERIALS u-top tm covid-19 detection kit
Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.
U Top Tm Covid 19 Detection Kit, supplied by SEASUN BIOMATERIALS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/aq+top+covid+19+rapid+detection+kit/pmc09020431-126-13-19
Average 90 stars, based on 1 article reviews
u-top tm covid-19 detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Nirmidas Biotech covid-19 (sars-cov-2) igg/igm antibody detection kit
Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.
Covid 19 (Sars Cov 2) Igg/Igm Antibody Detection Kit, supplied by Nirmidas Biotech, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/covid+19++sars+cov+2++igm+igg+antibody+detection+kit/pmc09671206-928-3-0
Average 90 stars, based on 1 article reviews
covid-19 (sars-cov-2) igg/igm antibody detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SEASUN BIOMATERIALS ss-9930
Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.
Ss 9930, supplied by SEASUN BIOMATERIALS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/u+top+covid+19+detection+kit/pm34650067-54-8-9
Average 90 stars, based on 1 article reviews
ss-9930 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
NewGene Ltd covid-19 antigen detection kit
Sensitivity and specificity rates of antigen tests passing the validation, stratified according to the viral load. Numbers in brackets indicate the 95% confidence intervals.
Covid 19 Antigen Detection Kit, supplied by NewGene Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/covid+19+antigen+detection+kit/pmc08704317-2-2-0
Average 90 stars, based on 1 article reviews
covid-19 antigen detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Gnomegen Inc covid-19 detection assay
Sensitivity and specificity rates of antigen tests passing the validation, stratified according to the viral load. Numbers in brackets indicate the 95% confidence intervals.
Covid 19 Detection Assay, supplied by Gnomegen Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/covid+19+rt+digital+pcr+detection+kit/pm33222514-212-1-1
Average 90 stars, based on 1 article reviews
covid-19 detection assay - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Bioeksen R&D Technologies bio-speedy covid-19 rt-qpcr kit
Sensitivity and specificity rates of antigen tests passing the validation, stratified according to the viral load. Numbers in brackets indicate the 95% confidence intervals.
Bio Speedy Covid 19 Rt Qpcr Kit, supplied by Bioeksen R&D Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/bio+speedy++covid+19+rt+qpcr+detection+kit/ppr0409187-47-28-34
Average 90 stars, based on 1 article reviews
bio-speedy covid-19 rt-qpcr kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Genematrix inc neoplex tm covid-19 detection kit
Microbiota composition in <t>COVID-19</t> and control samples. Alpha- and beta-diversity (A,B) of controls (green, n = 15) and COVID-19 patients (red, n = 26). Variable Importance Plot (VIP, C ) shows: (i) discriminant species after PLS-DA in descending order of VIP score (bar length); (ii) the highest relative abundance depending on the cohort (central bar color) and the lowest one (edge bar color); (iii) fold ratio (FR) of the highest vs. the lowest relative abundance (bar thickness), and (iv) significant difference after Mann–Whitney U test (non-FDR, * p ≤ 0.05, ** p ≤ 0.01). Network analysis (D) shows communities of bacterial species (namely, species-interacting groups, SIGs) and their positive (red Pearson coefficient) or negative (blue Pearson coefficient) relative abundances correlation. Nodes are colored according to the cohort harboring the higher relative abundance for a definite species, and node name size is directly proportional to the “keystonness” (importance of a species within the overall network). Edge thickness is inversely proportional to the Pearson p -value after 10% Benjamini–Hochberg two-stages FDR, and it is colored according to positive (red) or negative (blue) Pearson coefficient. For each SIG are reported percentages of COVID-19- and controls-related species. Venn diagram (E) shows species distribution among the two cohorts considering all of the 122 species (not the core microbiota) retrieved by DADA2 pipeline. Volcano plot (F) highlights discriminant oral bacterial species in terms of their fold change ( X axis) and cologarithm of Mann–Whitney U test p -value (non-FDR) ( Y axis): species with zero relative abundance were not reported. Pairwise analysis (G) of selected 11 species (four for COVID-19—red and seven for controls—green) depicts significant differences in terms of relative abundance and prevalence. In each sub-graph are reported the p -value (from Mann–Whitney U test) and the fold ratio (FR) among COVID-19 and controls.
Neoplex Tm Covid 19 Detection Kit, supplied by Genematrix inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/neoplex+covid+19+detection+kit/pmc08361794-52-19-24
Average 90 stars, based on 1 article reviews
neoplex tm covid-19 detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Stilla Technologies digital pcr solution combined covid-19 detection kit
Summary of biomarkers of SARS-CoV-2 detection and COVID-19 diagnosis.
Digital Pcr Solution Combined Covid 19 Detection Kit, supplied by Stilla Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/digital+pcr+solution+combined+covid+19+detection+kit/pmc07435336-5-23-36
Average 90 stars, based on 1 article reviews
digital pcr solution combined covid-19 detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Shanghai Fosun Pharmaceutical covid-19 rt-pcr detection kit
Summary of biomarkers of SARS-CoV-2 detection and COVID-19 diagnosis.
Covid 19 Rt Pcr Detection Kit, supplied by Shanghai Fosun Pharmaceutical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/covid+19+rt+pcr+detection+kit/10__24293_slash_ijcpml__v28i3__1895-70-2-1
Average 90 stars, based on 1 article reviews
covid-19 rt-pcr detection kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Shanghai Fosun Long March Medical Science real-time pcr kit
Summary of biomarkers of SARS-CoV-2 detection and COVID-19 diagnosis.
Real Time Pcr Kit, supplied by Shanghai Fosun Long March Medical Science, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/covid-19+detection/fosun+covid+19+rt+pcr+detection+kit/pmc08267197-28-45-52
Average 90 stars, based on 1 article reviews
real-time pcr kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.

Journal: Diagnostics

Article Title: Nucleic Acid-Based Diagnostic Tests for the Detection SARS-CoV-2: An Update

doi: 10.3390/diagnostics11010053

Figure Lengend Snippet: Comparison of various FDA-EUA NATs for the detection of SARS-CoV-2.

Article Snippet: Atila BioSystems, Inc. , iAMP COVID-19 Detection Kit , H , Orf1ab , N , 10 copies/μL.

Techniques: Comparison, Quantitative RT-PCR, Control, Multiplex Assay, Real-time Polymerase Chain Reaction, Diagnostic Assay, Reverse Transcription, Reverse Transcription Polymerase Chain Reaction, Virus, Luminex, Fluorescence, Extraction, Amplification, CRISPR, Sequencing

Sensitivity and specificity rates of antigen tests passing the validation, stratified according to the viral load. Numbers in brackets indicate the 95% confidence intervals.

Journal: Microorganisms

Article Title: Multicenter Technical Validation of 30 Rapid Antigen Tests for the Detection of SARS-CoV-2 (VALIDATE)

doi: 10.3390/microorganisms9122589

Figure Lengend Snippet: Sensitivity and specificity rates of antigen tests passing the validation, stratified according to the viral load. Numbers in brackets indicate the 95% confidence intervals.

Article Snippet: Newgene—Hangzhou-Bioengineering , COVID-19 Antigen Detection Kit , 81.7% (69.6, 90.5) , 94.1% (83.8, 98.8) , 97.8% (88.2, 99.9) , 99%.

Techniques: Antigen Assay

Microbiota composition in COVID-19 and control samples. Alpha- and beta-diversity (A,B) of controls (green, n = 15) and COVID-19 patients (red, n = 26). Variable Importance Plot (VIP, C ) shows: (i) discriminant species after PLS-DA in descending order of VIP score (bar length); (ii) the highest relative abundance depending on the cohort (central bar color) and the lowest one (edge bar color); (iii) fold ratio (FR) of the highest vs. the lowest relative abundance (bar thickness), and (iv) significant difference after Mann–Whitney U test (non-FDR, * p ≤ 0.05, ** p ≤ 0.01). Network analysis (D) shows communities of bacterial species (namely, species-interacting groups, SIGs) and their positive (red Pearson coefficient) or negative (blue Pearson coefficient) relative abundances correlation. Nodes are colored according to the cohort harboring the higher relative abundance for a definite species, and node name size is directly proportional to the “keystonness” (importance of a species within the overall network). Edge thickness is inversely proportional to the Pearson p -value after 10% Benjamini–Hochberg two-stages FDR, and it is colored according to positive (red) or negative (blue) Pearson coefficient. For each SIG are reported percentages of COVID-19- and controls-related species. Venn diagram (E) shows species distribution among the two cohorts considering all of the 122 species (not the core microbiota) retrieved by DADA2 pipeline. Volcano plot (F) highlights discriminant oral bacterial species in terms of their fold change ( X axis) and cologarithm of Mann–Whitney U test p -value (non-FDR) ( Y axis): species with zero relative abundance were not reported. Pairwise analysis (G) of selected 11 species (four for COVID-19—red and seven for controls—green) depicts significant differences in terms of relative abundance and prevalence. In each sub-graph are reported the p -value (from Mann–Whitney U test) and the fold ratio (FR) among COVID-19 and controls.

Journal: Frontiers in Microbiology

Article Title: Profiling of Oral Microbiota and Cytokines in COVID-19 Patients

doi: 10.3389/fmicb.2021.671813

Figure Lengend Snippet: Microbiota composition in COVID-19 and control samples. Alpha- and beta-diversity (A,B) of controls (green, n = 15) and COVID-19 patients (red, n = 26). Variable Importance Plot (VIP, C ) shows: (i) discriminant species after PLS-DA in descending order of VIP score (bar length); (ii) the highest relative abundance depending on the cohort (central bar color) and the lowest one (edge bar color); (iii) fold ratio (FR) of the highest vs. the lowest relative abundance (bar thickness), and (iv) significant difference after Mann–Whitney U test (non-FDR, * p ≤ 0.05, ** p ≤ 0.01). Network analysis (D) shows communities of bacterial species (namely, species-interacting groups, SIGs) and their positive (red Pearson coefficient) or negative (blue Pearson coefficient) relative abundances correlation. Nodes are colored according to the cohort harboring the higher relative abundance for a definite species, and node name size is directly proportional to the “keystonness” (importance of a species within the overall network). Edge thickness is inversely proportional to the Pearson p -value after 10% Benjamini–Hochberg two-stages FDR, and it is colored according to positive (red) or negative (blue) Pearson coefficient. For each SIG are reported percentages of COVID-19- and controls-related species. Venn diagram (E) shows species distribution among the two cohorts considering all of the 122 species (not the core microbiota) retrieved by DADA2 pipeline. Volcano plot (F) highlights discriminant oral bacterial species in terms of their fold change ( X axis) and cologarithm of Mann–Whitney U test p -value (non-FDR) ( Y axis): species with zero relative abundance were not reported. Pairwise analysis (G) of selected 11 species (four for COVID-19—red and seven for controls—green) depicts significant differences in terms of relative abundance and prevalence. In each sub-graph are reported the p -value (from Mann–Whitney U test) and the fold ratio (FR) among COVID-19 and controls.

Article Snippet: SARS-CoV-2 detection was performed on the CFX96 TM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, United States), using the NeoPlex TM COVID-19 Detection Kit (GeneMatrix, Seongnam, Kyonggi-do, South Korea) targeting viral N and RdRp genes and the housekeeping gene of β-actin as internal control, following the manufacturer’s instructions.

Techniques: MANN-WHITNEY

Cytokine pattern in COVID-19 and controls. Cohort separation of controls (green, n = 17) and COVID-19 patients (red, n = 7) based on cytokine profiles, shown by Principal Coordinate Analysis (PCoA, A ) and Hierarchical Clustering Analysis (HCA, B ), following the Bray–Curtis distance algorithm. Volcano plot (C) highlights discriminant oral cytokines in terms of their fold change ( X axis) and cologarithm of Mann–Whitney U test p -value (non-FDR) ( Y axis). Variable Importance Plot (VIP, D ) shows: (i) discriminant cytokines after PLS-DA in descending order of VIP score (bar length); (ii) the highest cytokine quantity (pg/ml) depending on the cohort (central bar color) and the lowest one (edge bar color); (iii) fold ratio (FR) of the highest vs. the lowest cytokine quantity (pg/ml) (bar thickness) and iv) significant difference after Mann–Whitney U test (non-FDR, ** p ≤ 0.01; *** p ≤ 0.001). Pairwise analysis (E) of selected two cytokines depicts significant differences in terms of quantity (pg/ml), reporting p -value (from Mann–Whitney U test) and fold ratio (FR) among COVID-19 and controls. Pearson linear correlation (F) on non-normalized and non-standardized oral ( X axis) and serum ( Y axis) cytokines levels (pg/ml), showing significant positive correlation among the two cytokine patterns. Outlier cytokines having extreme values (IL-1Ra, IL-15, and PDGF-bb) were excluded from linear correlation analysis.

Journal: Frontiers in Microbiology

Article Title: Profiling of Oral Microbiota and Cytokines in COVID-19 Patients

doi: 10.3389/fmicb.2021.671813

Figure Lengend Snippet: Cytokine pattern in COVID-19 and controls. Cohort separation of controls (green, n = 17) and COVID-19 patients (red, n = 7) based on cytokine profiles, shown by Principal Coordinate Analysis (PCoA, A ) and Hierarchical Clustering Analysis (HCA, B ), following the Bray–Curtis distance algorithm. Volcano plot (C) highlights discriminant oral cytokines in terms of their fold change ( X axis) and cologarithm of Mann–Whitney U test p -value (non-FDR) ( Y axis). Variable Importance Plot (VIP, D ) shows: (i) discriminant cytokines after PLS-DA in descending order of VIP score (bar length); (ii) the highest cytokine quantity (pg/ml) depending on the cohort (central bar color) and the lowest one (edge bar color); (iii) fold ratio (FR) of the highest vs. the lowest cytokine quantity (pg/ml) (bar thickness) and iv) significant difference after Mann–Whitney U test (non-FDR, ** p ≤ 0.01; *** p ≤ 0.001). Pairwise analysis (E) of selected two cytokines depicts significant differences in terms of quantity (pg/ml), reporting p -value (from Mann–Whitney U test) and fold ratio (FR) among COVID-19 and controls. Pearson linear correlation (F) on non-normalized and non-standardized oral ( X axis) and serum ( Y axis) cytokines levels (pg/ml), showing significant positive correlation among the two cytokine patterns. Outlier cytokines having extreme values (IL-1Ra, IL-15, and PDGF-bb) were excluded from linear correlation analysis.

Article Snippet: SARS-CoV-2 detection was performed on the CFX96 TM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, United States), using the NeoPlex TM COVID-19 Detection Kit (GeneMatrix, Seongnam, Kyonggi-do, South Korea) targeting viral N and RdRp genes and the housekeeping gene of β-actin as internal control, following the manufacturer’s instructions.

Techniques: MANN-WHITNEY

Integration of oral species and cytokines datasets. Network analysis (A) shows communities (namely, GREEN for controls and RED for COVID-19) of bacterial species and cytokines and their positive (red Pearson coefficient) or negative (blue Pearson coefficient) abundances (relative percentage or pg/ml, respectively, for species and cytokines) correlation. Nodes are colored according to the cohort harboring the higher abundance for a definite species or cytokine, and node name size is directly proportional to the “keystonness” (importance of a species or cytokine within the overall network). Edge thickness is inversely proportional to the Pearson p -value after 10% Benjamini–Hochberg two-stages FDR, and it is colored according to positive (red) or negative (blue) Pearson coefficient. For each community are reported percentages of COVID-19- and controls-related nodes. Dashed line represents a “structural gap” (a bunch of negative Pearson correlation edges) between GREEN and RED communities. Correlogram (B) of bacterial species and cytokines shows positive (red) or negative (blue) Pearson correlation on normalized and standardized abundances. Significant correlation is marked with an asterisk inside each square: only species or cytokines having at least one significant correlation were reported. Dendrograms on the x and y axes were generated following Bray–Curtis similarity, evidencing three different clusters for bacterial species (shown here within white boxes). Cytokines chosen to compute the C4 parameter (IL-12p70, IL-6) are highlighted with a colored box in the top dendrogram. The parameter C4 computed for each species is depicted as bar plot length at the right of the correlogram, highlighting the bad species (in red) or the good ones (in green). Scatterplots (C) among the four selected species and the two cytokines used to compute the C4 parameter: their abundances are negatively related to one another (normalized and standardized data), as reported by Pearson coefficient and p -value (95% confidence interval, gray area). Kernel Density Estimation (KDE) plots (D) report on X axis the normalized and standardized abundance of the selected species and cytokines and on Y axis the subjects’ distribution, divided by COVID-19 (red) and controls (green).

Journal: Frontiers in Microbiology

Article Title: Profiling of Oral Microbiota and Cytokines in COVID-19 Patients

doi: 10.3389/fmicb.2021.671813

Figure Lengend Snippet: Integration of oral species and cytokines datasets. Network analysis (A) shows communities (namely, GREEN for controls and RED for COVID-19) of bacterial species and cytokines and their positive (red Pearson coefficient) or negative (blue Pearson coefficient) abundances (relative percentage or pg/ml, respectively, for species and cytokines) correlation. Nodes are colored according to the cohort harboring the higher abundance for a definite species or cytokine, and node name size is directly proportional to the “keystonness” (importance of a species or cytokine within the overall network). Edge thickness is inversely proportional to the Pearson p -value after 10% Benjamini–Hochberg two-stages FDR, and it is colored according to positive (red) or negative (blue) Pearson coefficient. For each community are reported percentages of COVID-19- and controls-related nodes. Dashed line represents a “structural gap” (a bunch of negative Pearson correlation edges) between GREEN and RED communities. Correlogram (B) of bacterial species and cytokines shows positive (red) or negative (blue) Pearson correlation on normalized and standardized abundances. Significant correlation is marked with an asterisk inside each square: only species or cytokines having at least one significant correlation were reported. Dendrograms on the x and y axes were generated following Bray–Curtis similarity, evidencing three different clusters for bacterial species (shown here within white boxes). Cytokines chosen to compute the C4 parameter (IL-12p70, IL-6) are highlighted with a colored box in the top dendrogram. The parameter C4 computed for each species is depicted as bar plot length at the right of the correlogram, highlighting the bad species (in red) or the good ones (in green). Scatterplots (C) among the four selected species and the two cytokines used to compute the C4 parameter: their abundances are negatively related to one another (normalized and standardized data), as reported by Pearson coefficient and p -value (95% confidence interval, gray area). Kernel Density Estimation (KDE) plots (D) report on X axis the normalized and standardized abundance of the selected species and cytokines and on Y axis the subjects’ distribution, divided by COVID-19 (red) and controls (green).

Article Snippet: SARS-CoV-2 detection was performed on the CFX96 TM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, United States), using the NeoPlex TM COVID-19 Detection Kit (GeneMatrix, Seongnam, Kyonggi-do, South Korea) targeting viral N and RdRp genes and the housekeeping gene of β-actin as internal control, following the manufacturer’s instructions.

Techniques: Generated

Consortia of bacteria and cytokines predict COVID-19 status. Receiver Operating Characteristic (ROC) with fivefold cross-validation and C-Support Vector Machine classifier was employed to assess the best oral bacterial species (among 11 selected, (A) or species plus cytokines (among 19 selected, (B) able to predict COVID-19 status. Each panel reports the best five Area Under Curve (AUC) values in descending order (see the inset legend also showing specificity, Sp, and sensitivity, Se, for each ROC curve), plus a sixth curve encompassing the preceding five grouped. Combinations were computed for selected species ( n = 11, 2,047 combinations, (C) and species plus cytokines ( n = 19, 524,287 combinations, (D) , and the best “consortia” predicting COVID-19 are shown along with their AUC, Sp and Se values. BacCOV (E) and CytoCOV (F) parameters were computed and divided into their GREEN (species and cytokines higher in controls) and RED (species and cytokines higher in COVID-19) components and employed to generate scatterplot 2D graphs. Abundance thresholds (computed as in ) are shown as dotted gray lines, and their values are reported in bold. In each quadrant of panels E and F are reported the percentages of controls (green) or COVID-19 subjects (red).

Journal: Frontiers in Microbiology

Article Title: Profiling of Oral Microbiota and Cytokines in COVID-19 Patients

doi: 10.3389/fmicb.2021.671813

Figure Lengend Snippet: Consortia of bacteria and cytokines predict COVID-19 status. Receiver Operating Characteristic (ROC) with fivefold cross-validation and C-Support Vector Machine classifier was employed to assess the best oral bacterial species (among 11 selected, (A) or species plus cytokines (among 19 selected, (B) able to predict COVID-19 status. Each panel reports the best five Area Under Curve (AUC) values in descending order (see the inset legend also showing specificity, Sp, and sensitivity, Se, for each ROC curve), plus a sixth curve encompassing the preceding five grouped. Combinations were computed for selected species ( n = 11, 2,047 combinations, (C) and species plus cytokines ( n = 19, 524,287 combinations, (D) , and the best “consortia” predicting COVID-19 are shown along with their AUC, Sp and Se values. BacCOV (E) and CytoCOV (F) parameters were computed and divided into their GREEN (species and cytokines higher in controls) and RED (species and cytokines higher in COVID-19) components and employed to generate scatterplot 2D graphs. Abundance thresholds (computed as in ) are shown as dotted gray lines, and their values are reported in bold. In each quadrant of panels E and F are reported the percentages of controls (green) or COVID-19 subjects (red).

Article Snippet: SARS-CoV-2 detection was performed on the CFX96 TM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, United States), using the NeoPlex TM COVID-19 Detection Kit (GeneMatrix, Seongnam, Kyonggi-do, South Korea) targeting viral N and RdRp genes and the housekeeping gene of β-actin as internal control, following the manufacturer’s instructions.

Techniques: Plasmid Preparation

Consortia of bacteria predict COVID-19 ageusia/hyposmia. Mixed graphs for COVID-19 patients having ageusia/hyposmia (A) are made of VIP plot, volcano plot and boxplot of relative abundances for selected species. Description for these plots as in , . Significant difference after Mann–Whitney U test (non-FDR, * p < = 0.05, ** p < = 0.01). Receiver Operating Characteristic (ROC) with fivefold cross-validation and C-Support Vector Machine classifier (B) was built for each one of the selected species plus their combined effect on predicting the presence of ageusia/hyposmia (“yes,” blue) in respect to their absence (“no,” orange). Panel B reports Area Under Curve (AUC), specificity (Sp), and sensitivity (Se) values for each ROC curve. Confusion matrix (C) was employed to evaluate the quality of the output of the C-Support Vector Machine classifier used to generate ROC curves. The diagonal elements represent the percentage of patients (referred to the blue shadowed sidebar) for which the predicted label ( X axis) is equal to the true label ( Y axis), while off-diagonal elements are those that are mislabeled by the classifier. Scatterplot (D) among the two selected species shows how their relative abundances are positively related to one another (normalized and standardized data), as reported by Pearson coefficient and p -value (95% confidence interval, gray area). Raw relative abundances of selected species were used to generate a scatterplot (E) to ease a clinical interpretation of patients’ distribution into the 2D space. Abundance thresholds are shown as truncated dotted gray lines, and their values are reported in bold: percentages of patients separated by these boundaries are reported in bold.

Journal: Frontiers in Microbiology

Article Title: Profiling of Oral Microbiota and Cytokines in COVID-19 Patients

doi: 10.3389/fmicb.2021.671813

Figure Lengend Snippet: Consortia of bacteria predict COVID-19 ageusia/hyposmia. Mixed graphs for COVID-19 patients having ageusia/hyposmia (A) are made of VIP plot, volcano plot and boxplot of relative abundances for selected species. Description for these plots as in , . Significant difference after Mann–Whitney U test (non-FDR, * p < = 0.05, ** p < = 0.01). Receiver Operating Characteristic (ROC) with fivefold cross-validation and C-Support Vector Machine classifier (B) was built for each one of the selected species plus their combined effect on predicting the presence of ageusia/hyposmia (“yes,” blue) in respect to their absence (“no,” orange). Panel B reports Area Under Curve (AUC), specificity (Sp), and sensitivity (Se) values for each ROC curve. Confusion matrix (C) was employed to evaluate the quality of the output of the C-Support Vector Machine classifier used to generate ROC curves. The diagonal elements represent the percentage of patients (referred to the blue shadowed sidebar) for which the predicted label ( X axis) is equal to the true label ( Y axis), while off-diagonal elements are those that are mislabeled by the classifier. Scatterplot (D) among the two selected species shows how their relative abundances are positively related to one another (normalized and standardized data), as reported by Pearson coefficient and p -value (95% confidence interval, gray area). Raw relative abundances of selected species were used to generate a scatterplot (E) to ease a clinical interpretation of patients’ distribution into the 2D space. Abundance thresholds are shown as truncated dotted gray lines, and their values are reported in bold: percentages of patients separated by these boundaries are reported in bold.

Article Snippet: SARS-CoV-2 detection was performed on the CFX96 TM Real-Time PCR Detection System (Bio-Rad, Hercules, CA, United States), using the NeoPlex TM COVID-19 Detection Kit (GeneMatrix, Seongnam, Kyonggi-do, South Korea) targeting viral N and RdRp genes and the housekeeping gene of β-actin as internal control, following the manufacturer’s instructions.

Techniques: MANN-WHITNEY, Plasmid Preparation

Summary of biomarkers of SARS-CoV-2 detection and COVID-19 diagnosis.

Journal: Advances in Biomarker Sciences and Technology

Article Title: Biomarkers of COVID-19 and technologies to combat SARS-CoV-2

doi: 10.1016/j.abst.2020.08.001

Figure Lengend Snippet: Summary of biomarkers of SARS-CoV-2 detection and COVID-19 diagnosis.

Article Snippet: , Digital PCR , Digital PCR Point-of-care detection , Naica™ System , Stilla Technologies , No , Digital PCR solution combined with a COVID-19 detection kit that can identify SARS-CoV-2 and measure its viral load. , https://www.stillatechnologies.com/wp-content/uploads/2020/05/PR_StillaTechnologies_COVID_19_04052020-1.pdf.

Techniques: Digital PCR, CRISPR, Enzyme-linked Immunosorbent Assay, Recombinant

Schematic of serological antibody treatment and prevention for COVID-19. a) Convalescent serum therapy; and, b) Antibody testing by a lateral flow assay.

Journal: Advances in Biomarker Sciences and Technology

Article Title: Biomarkers of COVID-19 and technologies to combat SARS-CoV-2

doi: 10.1016/j.abst.2020.08.001

Figure Lengend Snippet: Schematic of serological antibody treatment and prevention for COVID-19. a) Convalescent serum therapy; and, b) Antibody testing by a lateral flow assay.

Article Snippet: , Digital PCR , Digital PCR Point-of-care detection , Naica™ System , Stilla Technologies , No , Digital PCR solution combined with a COVID-19 detection kit that can identify SARS-CoV-2 and measure its viral load. , https://www.stillatechnologies.com/wp-content/uploads/2020/05/PR_StillaTechnologies_COVID_19_04052020-1.pdf.

Techniques: Lateral Flow Assay