|
COMSOL Inc
hydrodynamic resistance simulation Hydrodynamic Resistance Simulation, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamic+resistance+simulation/us12297417-207-6-10 Average 90 stars, based on 1 article reviews
hydrodynamic resistance simulation - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
hydrodynamic simulations Hydrodynamic Simulations, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamic+simulation/10__1016_slash_j__mee__2016__03__005-32-11-13 Average 90 stars, based on 1 article reviews
hydrodynamic simulations - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
hydrodynamic flow simulation software Hydrodynamic Flow Simulation Software, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamic+flow+simulation+software/pmc04129156-3-9-9 Average 90 stars, based on 1 article reviews
hydrodynamic flow simulation software - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
comsol hydrodynamics simulations Comsol Hydrodynamics Simulations, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/comsol+hydrodynamics+simulation/10__1039_slash_c8gc01917g-191-1-0 Average 90 stars, based on 1 article reviews
comsol hydrodynamics simulations - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
hydrodynamic simulation comsol Hydrodynamic Simulation Comsol, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamic+simulation+comsol/pmc11697305-211-10-11 Average 90 stars, based on 1 article reviews
hydrodynamic simulation comsol - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
simulated hydrodynamic flow ![]() Simulated Hydrodynamic Flow, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/simulated+hydrodynamic+flow/pmc09356744-110-54-52 Average 90 stars, based on 1 article reviews
simulated hydrodynamic flow - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
electro-hydrodynamic simulations ![]() Electro Hydrodynamic Simulations, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/electro+hydrodynamic+simulations/ppr0557330-77-2-18 Average 90 stars, based on 1 article reviews
electro-hydrodynamic simulations - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
simulation of hydrodynamics for a lab scale ultrasonic batch reactor ![]() Simulation Of Hydrodynamics For A Lab Scale Ultrasonic Batch Reactor, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/simulation+of+hydrodynamics+for+a+lab+scale+ultrasonic+batch+reactor/pm26384902-215-2-11 Average 90 stars, based on 1 article reviews
simulation of hydrodynamics for a lab scale ultrasonic batch reactor - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
hydrodynamic numerical simulations ![]() Hydrodynamic Numerical Simulations, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamic+numerical+simulations/pmc10708091-73-1-8 Average 90 stars, based on 1 article reviews
hydrodynamic numerical simulations - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
hydrodynamics simulation ![]() Hydrodynamics Simulation, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/hydrodynamics+simulation/pmc08851462__pnas__2115496119__sapp-266-11-16 Average 90 stars, based on 1 article reviews
hydrodynamics simulation - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
computational hydrodynamic simulations ![]() Computational Hydrodynamic Simulations, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/computational+hydrodynamic+simulations/pm39226031__es4c06120_si_001-82-4-4 Average 90 stars, based on 1 article reviews
computational hydrodynamic simulations - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
COMSOL Inc
argon-doped ethanol plasma jet hydrodynamic simulation model ![]() Argon Doped Ethanol Plasma Jet Hydrodynamic Simulation Model, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/comsol+hydrodynamics+simulation/argon+doped+ethanol+plasma+jet+hydrodynamic+simulation+model/10__1088_slash_1361___6595_slash_ad716b-154-2-13 Average 90 stars, based on 1 article reviews
argon-doped ethanol plasma jet hydrodynamic simulation model - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Flow (Cambridge, England)
Article Title: Fluidic operation of a polymer-based nanosensor chip for analysing single molecules
doi: 10.1017/flo.2022.8
Figure Lengend Snippet: (a) Schematic of the nanosensor. The nanosensor is placed between two micrometre-sized access channels and is comprised of three main features; 20 baffles of 7 μm ×7 μm each to distribute reagents; 8-pillar arrays containing 268 pillars/array to perform solid-phase biological reactions; and 8 nano-tubes of 50 nm × 50 nm × 50 μm (w × d × l). (b) Sample processing steps carried out by the nanosensor that are enabled by hydrodynamic flow, which included pumping reagents (avidin) required for the solid-phase reactions (1); target DNA molecules immobilized onto the pillars of the array (2); and solid-phase reactions performed by adding the necessary reagents (3). (c) Electrokinetic flow is performed on the nanosensor chip and in the first step, the reaction is performed (1) followed by the products electrokinetically driven into the flight tubes through application of a DC voltage by placing electrodes at the end of the microchannel and grounding the ends of each nano-tube (2). Finally, once the products enter the nano-tube, they are detected using electrical measurements and the time-of-flight deduced for single DNA molecules to allow for their identification (3).
Article Snippet: For electrokinetic pumping, the electrostatics module (AC/DC physics) governed by the Poisson and Maxwell equations were chosen to model the electric field in the nanosensor by application of 10 V at the common input and placing earth ground at the outlet end of each nanoscale tube. shows the overall profile of the
Techniques: Avidin-Biotin Assay
Journal: Flow (Cambridge, England)
Article Title: Fluidic operation of a polymer-based nanosensor chip for analysing single molecules
doi: 10.1017/flo.2022.8
Figure Lengend Snippet: (a) COMSOL simulation of hydrodynamic flow of 1× TBE through the nanosensor device at a flow rate of 1 nl s −1 . The entrance of the nanosensor (25 μm) is used as the common inlet of the sampling/reagents. The flow entering the nanosensor is distributed uniformly across the pillar arrays by the baffles such that all 8 pillar arrays receive a constant delivery of the input fluid. (b) Graph showing the simulated average velocity across the 8-pillar arrays, which is ~3.7 mm s −1 . The velocity across the 8 pillar arrays possessed a standard deviation of 6 μm s −1 between the arrays. (c) Hydrodynamic flow across the 8 nano-tubes, where the flow was found to be negligible. This is empirically represented in the line graph that is drawn across the flight tubes, where the velocity at the entrance of the nano-tubes dropped to ~0 mm s −1 . (d) Pressure drop across the pillar arrays, where the average pressure drop among the 8 pillar arrays were found to be similar. (e) The pressure drop across the 8 nanochannel nano-tubes with respect to the pressure drop seen in the microchannels that are between the nano-tubes.
Article Snippet: For electrokinetic pumping, the electrostatics module (AC/DC physics) governed by the Poisson and Maxwell equations were chosen to model the electric field in the nanosensor by application of 10 V at the common input and placing earth ground at the outlet end of each nanoscale tube. shows the overall profile of the
Techniques: Sampling, Standard Deviation
Journal: Flow (Cambridge, England)
Article Title: Fluidic operation of a polymer-based nanosensor chip for analysing single molecules
doi: 10.1017/flo.2022.8
Figure Lengend Snippet: Experimental results of the hydrodynamic flow across the nanosensor. (a) Distribution of Rhodamine-B with hydrodynamic flow at a flow rate of 1 nl s −1 . The dye was distributed across the pillar arrays by the baffles and preferentially into the microchannel areas surrounding the nano-tubes. No visible fluorescence was seen in the nano-tubes. (b) Fluorescence intensities across the 8 pillar arrays showing similar levels of intensities ranging from 800–950 (arbitrary units). The intensities were represented as grey-scale values. (c) The fluorescence intensity of the dye tracer was also evaluated in the nano-tubes, and a significant intensity drop was seen in the 8 nano-tubes. Areas having dye had a grey value >800, while the intensity in the nanochannels were ~300. The measurements were taken from 5 different experiments and used to calculate the mean and standard deviation. No statistically significant difference was observed between the intensity in the pillar arrays (p < 0.01 at 95 % CI). A scale bar of 20 μm is represented in the images. The fluorescence was captured using a sCMOS camera at an exposure time of 10 ms with the fluorescence collected using a 100× oil immersion objective. For the fluorescence measurements, the fluorescence intensity from the image in the presence of dye was measured in arbitrary units (14-bit camera setting; 16 384-grey-scale image) from the imaging camera and the background signal, also measured in arbitrary units with the same grey scale, was subtracted from the dye measurements.
Article Snippet: For electrokinetic pumping, the electrostatics module (AC/DC physics) governed by the Poisson and Maxwell equations were chosen to model the electric field in the nanosensor by application of 10 V at the common input and placing earth ground at the outlet end of each nanoscale tube. shows the overall profile of the
Techniques: Fluorescence, Standard Deviation, Imaging