co2-laser puller p2000 Search Results


93
Sutter Instrument Company fiber puller
Fiber Puller, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/P-2000%2FF+Laser-Based+Fiber+Puller/pmc03658720-17-5-8
Average 93 stars, based on 1 article reviews
fiber puller - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

98
Sutter Instrument Company co2 laser puller
Co2 Laser Puller, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/Borosilicate+Glass/pm38963641__es4c01604_si_001-2-17-20
Average 98 stars, based on 1 article reviews
co2 laser puller - by Bioz Stars, 2026-09
98/100 stars
  Buy from Supplier

93
AutoMate Scientific Inc p-2000 pipette puller
P 2000 Pipette Puller, supplied by AutoMate Scientific Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/P-2000+Pipette+Puller/custom%40su_p_2000_f%40pm31917592__nl9b04640_si_001
Average 93 stars, based on 1 article reviews
p-2000 pipette puller - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

90
Sutter Instrument p- 2000 co2 laser–based puller
P 2000 Co2 Laser–Based Puller, supplied by Sutter Instrument, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/horizontal+puller/pm39630900-266-33-34
Average 90 stars, based on 1 article reviews
p- 2000 co2 laser–based puller - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Harvard Bioscience borosilicate filamented capillaries
Borosilicate Filamented Capillaries, supplied by Harvard Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/borosilicate+glass+capillaries/pm32521997-40-7-11
Average 90 stars, based on 1 article reviews
borosilicate filamented capillaries - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Warner Instruments sicm probe glass nano pipette
Sicm Probe Glass Nano Pipette, supplied by Warner Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/glass+pipette+theta/10__1038_slash_srep26687__-179-1-16
Average 86 stars, based on 1 article reviews
sicm probe glass nano pipette - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Friedrich & Dimmock quartz filamented capillaries
Quartz Filamented Capillaries, supplied by Friedrich & Dimmock, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/quartz+filamented+capillaries/10__1039_slash_c8fd00028j-101-7-11
Average 90 stars, based on 1 article reviews
quartz filamented capillaries - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

96
World Precision Instruments standard glass capillaries-1b150f-6
Standard Glass Capillaries 1b150f 6, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/Standard+Glass+Capillaries-1B150F-6/custom%401b150f-6%4010%2E1039%2Fd1ra01277k
Average 96 stars, based on 1 article reviews
standard glass capillaries-1b150f-6 - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

96
JEOL benchtop sem
Benchtop Sem, supplied by JEOL, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/JCM-6000+Scanning+Electron+Microscope/pm35219809-97-29-32
Average 96 stars, based on 1 article reviews
benchtop sem - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

95
World Precision Instruments microfil-mf34g-5
Microfil Mf34g 5, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/MicroFil-MF34G-5/custom%40mf34g-5%4031589026
Average 95 stars, based on 1 article reviews
microfil-mf34g-5 - by Bioz Stars, 2026-09
95/100 stars
  Buy from Supplier

90
Hilgenberg gmbh quartz capillaries hilgenberg
Verification and repeated measurement on sample. (A) Illustration of the scanning pathway taken by the SICS. The sample is scanned for multiple molecules by rastering the pipette across the sample in a snake-like manner (first along an X direction (continuously scan) and then a shift in Y , stepwise 1 μm). (B) Histogram of data collected for three different samples compared with control experiments in free translocation. We achieve significantly higher rates of detection with our SICS based approach when compared to free translocation experiments. (C) Contour plots of the integrated current blockade vs height of the signal from 3 different <t>capillary</t> measurements ( N cap1 = 23, N cap2 = 72, N cap3 = 39). We observe 2 different clusterings of the signal which we associate to either the presence of the aptamer only or thrombin bound conditions. Insertion: Each sensed molecule was characterized by measuring its height and blockage area.
Quartz Capillaries Hilgenberg, supplied by Hilgenberg gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/quartz+capillaries+hilgenberg/pmc11984302-144-0-2
Average 90 stars, based on 1 article reviews
quartz capillaries hilgenberg - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Corning Life Sciences borosilicate pipettes corning 7052 glass
Verification and repeated measurement on sample. (A) Illustration of the scanning pathway taken by the SICS. The sample is scanned for multiple molecules by rastering the pipette across the sample in a snake-like manner (first along an X direction (continuously scan) and then a shift in Y , stepwise 1 μm). (B) Histogram of data collected for three different samples compared with control experiments in free translocation. We achieve significantly higher rates of detection with our SICS based approach when compared to free translocation experiments. (C) Contour plots of the integrated current blockade vs height of the signal from 3 different <t>capillary</t> measurements ( N cap1 = 23, N cap2 = 72, N cap3 = 39). We observe 2 different clusterings of the signal which we associate to either the presence of the aptamer only or thrombin bound conditions. Insertion: Each sensed molecule was characterized by measuring its height and blockage area.
Borosilicate Pipettes Corning 7052 Glass, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/co2-laser+puller+p2000/patch+clamp+pipettes+corning+7052+glass/10__1016_slash_s0006___3495_ascii40_02_ascii41_75268___5-52-4-4
Average 90 stars, based on 1 article reviews
borosilicate pipettes corning 7052 glass - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Verification and repeated measurement on sample. (A) Illustration of the scanning pathway taken by the SICS. The sample is scanned for multiple molecules by rastering the pipette across the sample in a snake-like manner (first along an X direction (continuously scan) and then a shift in Y , stepwise 1 μm). (B) Histogram of data collected for three different samples compared with control experiments in free translocation. We achieve significantly higher rates of detection with our SICS based approach when compared to free translocation experiments. (C) Contour plots of the integrated current blockade vs height of the signal from 3 different capillary measurements ( N cap1 = 23, N cap2 = 72, N cap3 = 39). We observe 2 different clusterings of the signal which we associate to either the presence of the aptamer only or thrombin bound conditions. Insertion: Each sensed molecule was characterized by measuring its height and blockage area.

Journal: ACS Nano

Article Title: Controlled Sensing of User-Defined Aptamer-Based Targets Using Scanning Ionic Conductance Spectroscopy

doi: 10.1021/acsnano.4c18509

Figure Lengend Snippet: Verification and repeated measurement on sample. (A) Illustration of the scanning pathway taken by the SICS. The sample is scanned for multiple molecules by rastering the pipette across the sample in a snake-like manner (first along an X direction (continuously scan) and then a shift in Y , stepwise 1 μm). (B) Histogram of data collected for three different samples compared with control experiments in free translocation. We achieve significantly higher rates of detection with our SICS based approach when compared to free translocation experiments. (C) Contour plots of the integrated current blockade vs height of the signal from 3 different capillary measurements ( N cap1 = 23, N cap2 = 72, N cap3 = 39). We observe 2 different clusterings of the signal which we associate to either the presence of the aptamer only or thrombin bound conditions. Insertion: Each sensed molecule was characterized by measuring its height and blockage area.

Article Snippet: Quartz capillaries (Hilgenberg GmbH, length 70 mm, outside diameter 0.5 mm, and inside diameter 0.2 mm) were pulled by using a CO2 laser puller (P-2000, Sutter Instruments) with the following protocol: Heat = 580, Fil = 0, Vel = 15, Del = 170, Pul = 0; Heat = 570, Fil = 0, Vel = 15, Del= 170, Pul = 200.

Techniques: Transferring, Control, Translocation Assay

Multiplex DNA carrier experiments. (A) Design of a DNA carrier with 2 gaps and attachment to the surface. (B) Examples of measurements done on DNA with 2 gaps and sample current traces showing 3 different cases. Case 1 : both gaps containing aptamers, in gap 1 is TBA1, in gap 2 is TBA2 Case 2 : both gaps containing aptamers but only one site (TBA2) contains an attached protein. Case 3 : both gaps containing aptamers and both sites with attached proteins. (C) Density function plot of repeated measurements with the same capillary ( N = 6). Top: Density function plot of the molecules that are thrombin bound only in gap 1 (TBA1). Bottom: Density function plot of the molecules that have thrombin-bound in both gaps 1 and 2. (D) Histogram of repeated measurements showing percentages of events sorted by the 5 different cases ( N = 3). (E) Aggregated data from repeated experiments. Overall binding percentages as detected by the SICS approach is shown in the 2 different cases (aptamer and aptamer bound to the thrombin). We achieve a much higher detection rate with the 2 gap system.

Journal: ACS Nano

Article Title: Controlled Sensing of User-Defined Aptamer-Based Targets Using Scanning Ionic Conductance Spectroscopy

doi: 10.1021/acsnano.4c18509

Figure Lengend Snippet: Multiplex DNA carrier experiments. (A) Design of a DNA carrier with 2 gaps and attachment to the surface. (B) Examples of measurements done on DNA with 2 gaps and sample current traces showing 3 different cases. Case 1 : both gaps containing aptamers, in gap 1 is TBA1, in gap 2 is TBA2 Case 2 : both gaps containing aptamers but only one site (TBA2) contains an attached protein. Case 3 : both gaps containing aptamers and both sites with attached proteins. (C) Density function plot of repeated measurements with the same capillary ( N = 6). Top: Density function plot of the molecules that are thrombin bound only in gap 1 (TBA1). Bottom: Density function plot of the molecules that have thrombin-bound in both gaps 1 and 2. (D) Histogram of repeated measurements showing percentages of events sorted by the 5 different cases ( N = 3). (E) Aggregated data from repeated experiments. Overall binding percentages as detected by the SICS approach is shown in the 2 different cases (aptamer and aptamer bound to the thrombin). We achieve a much higher detection rate with the 2 gap system.

Article Snippet: Quartz capillaries (Hilgenberg GmbH, length 70 mm, outside diameter 0.5 mm, and inside diameter 0.2 mm) were pulled by using a CO2 laser puller (P-2000, Sutter Instruments) with the following protocol: Heat = 580, Fil = 0, Vel = 15, Del = 170, Pul = 0; Heat = 570, Fil = 0, Vel = 15, Del= 170, Pul = 200.

Techniques: Multiplex Assay, Binding Assay