cell-search Search Results


90
CellSearch inc cell search unit 600
Cell Search Unit 600, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+unit+600/us08542571-192-8-18
Average 90 stars, based on 1 article reviews
cell search unit 600 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc cell search block 76
Cell Search Block 76, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+block+76/us08385482-87-0-1
Average 90 stars, based on 1 article reviews
cell search block 76 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc cell search csp engine
Cell Search Csp Engine, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+csp+engine/us07298775-65-8-8
Average 90 stars, based on 1 article reviews
cell search csp engine - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc circulating tumor cell kit
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Circulating Tumor Cell Kit, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/circulating+tumor+cell+kit/pmc07388446-144-11-18
Average 90 stars, based on 1 article reviews
circulating tumor cell kit - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc circulating melanoma cell kit
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Circulating Melanoma Cell Kit, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/the+circulating+melanoma+cell+kit/pmc06217324-24-12-6
Average 90 stars, based on 1 article reviews
circulating melanoma cell kit - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc lte cell search
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Lte Cell Search, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/lte+cell+search/us11627478-245-6-7
Average 90 stars, based on 1 article reviews
lte cell search - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc system and method for cell search enhancement in an lte system
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
System And Method For Cell Search Enhancement In An Lte System, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/system+and+method+for+cell+search+enhancement+in+an+lte+system/us09432922-2-14-9
Average 90 stars, based on 1 article reviews
system and method for cell search enhancement in an lte system - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc cell search signals
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Cell Search Signals, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+signals/us11876658-202-0-0
Average 90 stars, based on 1 article reviews
cell search signals - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc any cell search procedure
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Any Cell Search Procedure, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+procedure/us12101675-240-7-26
Average 90 stars, based on 1 article reviews
any cell search procedure - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc cell search method
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Cell Search Method, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+method/pm24166007-105-3-9
Average 90 stars, based on 1 article reviews
cell search method - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc magnest cell presentation device
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Magnest Cell Presentation Device, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/magnest+cell+presentation+device/pm15501967-65-11-15
Average 90 stars, based on 1 article reviews
magnest cell presentation device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CellSearch inc cell search unit 709
Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, <t>circulating</t> tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.
Cell Search Unit 709, supplied by CellSearch inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cell-search/cell+search+unit+709/us08798213-107-21-12
Average 90 stars, based on 1 article reviews
cell search unit 709 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, circulating tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: Flow chart of the schematic overview of the current study design for the genome-wide copy number analysis of CTCs of BCLM. CTCs, circulating tumor cells; BCLM, breast cancer liver metastasis; MLBACs, multiple annealing and looping based amplification cycles; CNVs, copy number variations; PET/CT, positron emission tomography/computed tomography.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques: Genome Wide, Multiple Annealing and Looping–Based Amplification Cycles, Positron Emission Tomography-Computed Tomography, Positron Emission Tomography, Computed Tomography

Analysis of CTCs in different patient samples. (A) Comparison of the CTC count between newly diagnosed liver metastases (n=23) and recurrent liver metastases (n=20) in a 7.5 ml blood sample of BCLM patients (n=43). In general, higher percentages of CTCs were observed in newly diagnosed BCLM patients (mean CTCs in newly diagnosed metastases 38.30 vs. 25.50 in recurrent metastases). (B) Linear logistic regression of CTC detection. Average (black line) CTC recovery was calculated by using the linear logistic regression from 43 BCLM patients. The cut-off levels (10 CTCs for expected and 5 CTCs for CellSearch per sample) are indicated by the dashed lines. *P<0.05. CTCs, circulating tumor cells; BCLM, breast cancer liver metastasis.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: Analysis of CTCs in different patient samples. (A) Comparison of the CTC count between newly diagnosed liver metastases (n=23) and recurrent liver metastases (n=20) in a 7.5 ml blood sample of BCLM patients (n=43). In general, higher percentages of CTCs were observed in newly diagnosed BCLM patients (mean CTCs in newly diagnosed metastases 38.30 vs. 25.50 in recurrent metastases). (B) Linear logistic regression of CTC detection. Average (black line) CTC recovery was calculated by using the linear logistic regression from 43 BCLM patients. The cut-off levels (10 CTCs for expected and 5 CTCs for CellSearch per sample) are indicated by the dashed lines. *P<0.05. CTCs, circulating tumor cells; BCLM, breast cancer liver metastasis.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques: Comparison

Gallery of fluorescent immunostaining of CTCs, EPCs and leukocytes (WBCs) from patients with BCLM. Cells were stained by anti-CD45-APC antibody, 4′,6-diamidino-2-phenylindole (DAPI, nuclear staining; pink color), anti-CK8-PE (green color). The CTC sample is characterized by a CD45 − /Nucleus + /CK8 + of a diameter <8 µm, while CD45 + /Nucleus + /CK8 − are identified as WBCs. Cells that stain CD45 − /Nucleus + /CK8 + are identified as EPCs with a diameter <8 µm (magnification 200 µm). BCLM, breast cancer liver metastasis; CTCs, circulating tumor cells; CK, cytokeratin; EPCs, epithelial cells; WBCs, white blood cells.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: Gallery of fluorescent immunostaining of CTCs, EPCs and leukocytes (WBCs) from patients with BCLM. Cells were stained by anti-CD45-APC antibody, 4′,6-diamidino-2-phenylindole (DAPI, nuclear staining; pink color), anti-CK8-PE (green color). The CTC sample is characterized by a CD45 − /Nucleus + /CK8 + of a diameter <8 µm, while CD45 + /Nucleus + /CK8 − are identified as WBCs. Cells that stain CD45 − /Nucleus + /CK8 + are identified as EPCs with a diameter <8 µm (magnification 200 µm). BCLM, breast cancer liver metastasis; CTCs, circulating tumor cells; CK, cytokeratin; EPCs, epithelial cells; WBCs, white blood cells.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques: Immunostaining, Staining

Visualization of 10× genome-wide gene copy number analysis between newly diagnosed liver metastases (A) CTCs from newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs from recurrent liver metastases (D) The histogram shows the frequency of genomic gains (blue) and losses (red) of CTCs. Most significant CNVs in each group are shown with star symbol (*). CTCs, circulating tumor cells; CNVs, copy number variations.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: Visualization of 10× genome-wide gene copy number analysis between newly diagnosed liver metastases (A) CTCs from newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs from recurrent liver metastases (D) The histogram shows the frequency of genomic gains (blue) and losses (red) of CTCs. Most significant CNVs in each group are shown with star symbol (*). CTCs, circulating tumor cells; CNVs, copy number variations.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques: Genome Wide

Heat map representation of CTC-shared CNVs in newly diagnosed liver metastases (A) CTCs of newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs of recurrent liver metastases (D) Heat map representation of frequently deregulated genes in different groups. CTCs, circulating tumor cells; CNVs, copy number variations.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: Heat map representation of CTC-shared CNVs in newly diagnosed liver metastases (A) CTCs of newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs of recurrent liver metastases (D) Heat map representation of frequently deregulated genes in different groups. CTCs, circulating tumor cells; CNVs, copy number variations.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques:

GSEA of different groups in newly diagnosed liver metastases (A) CTCs of newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs of recurrent liver metastases (D) The size and color intensity of a circle represents the numbers of genes and ∓log10 (P-value) for each group, respectively. GSEA, gene set enrichment analysis, CTCs, circulating tumor cells.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: GSEA of different groups in newly diagnosed liver metastases (A) CTCs of newly diagnosed liver metastases (B) recurrent liver metastases (C) and CTCs of recurrent liver metastases (D) The size and color intensity of a circle represents the numbers of genes and ∓log10 (P-value) for each group, respectively. GSEA, gene set enrichment analysis, CTCs, circulating tumor cells.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques:

PPI network of commonly deregulated targeted genes and pathways in newly diagnosed liver metastases (A), CTCs of newly diagnosed liver metastases (B), recurrent liver metastases (C) and CTCs of recurrent liver metastases (D). Filled color represents the -log2 (fold change) of each gene, and border orange color represents the module to which each gene belongs. CTCs, circulating tumor cells; PPI, protein-protein interaction.

Journal: Oncology Reports

Article Title: Genome-wide copy number analysis of circulating tumor cells in breast cancer patients with liver metastasis

doi: 10.3892/or.2020.7650

Figure Lengend Snippet: PPI network of commonly deregulated targeted genes and pathways in newly diagnosed liver metastases (A), CTCs of newly diagnosed liver metastases (B), recurrent liver metastases (C) and CTCs of recurrent liver metastases (D). Filled color represents the -log2 (fold change) of each gene, and border orange color represents the module to which each gene belongs. CTCs, circulating tumor cells; PPI, protein-protein interaction.

Article Snippet: CTCs from 7.5 ml blood sample were captured with the CellSearch Circulating Tumor Cell Kit (cat. no. K062013; Veridex, LLC) for 1 h at room temperature.

Techniques: