cd19 micro beads Search Results


98
Miltenyi Biotec cell sorting cd19 micro beads
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Cell Sorting Cd19 Micro Beads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cell sorting cd19 micro beads/product/Miltenyi Biotec
Average 98 stars, based on 1 article reviews
cell sorting cd19 micro beads - by Bioz Stars, 2026-03
98/100 stars
  Buy from Supplier

99
Miltenyi Biotec cd19 micro beads
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Cd19 Micro Beads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd19 micro beads/product/Miltenyi Biotec
Average 99 stars, based on 1 article reviews
cd19 micro beads - by Bioz Stars, 2026-03
99/100 stars
  Buy from Supplier

98
Miltenyi Biotec human cd19 micro beads
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Human Cd19 Micro Beads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/human cd19 micro beads/product/Miltenyi Biotec
Average 98 stars, based on 1 article reviews
human cd19 micro beads - by Bioz Stars, 2026-03
98/100 stars
  Buy from Supplier

90
Miltenyi Biotec cd3 micro beads
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Cd3 Micro Beads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd3 micro beads/product/Miltenyi Biotec
Average 90 stars, based on 1 article reviews
cd3 micro beads - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

98
Miltenyi Biotec cd4 cd8 cd14 cd19 micro beads
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Cd4 Cd8 Cd14 Cd19 Micro Beads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd4 cd8 cd14 cd19 micro beads/product/Miltenyi Biotec
Average 98 stars, based on 1 article reviews
cd4 cd8 cd14 cd19 micro beads - by Bioz Stars, 2026-03
98/100 stars
  Buy from Supplier

99
Miltenyi Biotec cd4 t cell isolation kit
Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using <t>CD19-microbeads</t> by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.
Cd4 T Cell Isolation Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd4 t cell isolation kit/product/Miltenyi Biotec
Average 99 stars, based on 1 article reviews
cd4 t cell isolation kit - by Bioz Stars, 2026-03
99/100 stars
  Buy from Supplier

Image Search Results


Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using CD19-microbeads by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.

Journal: Scientific Reports

Article Title: Establishment of induced pluripotent stem cells from normal B cells and inducing AID expression in their differentiation into hematopoietic progenitor cells

doi: 10.1038/s41598-017-01627-1

Figure Lengend Snippet: Cell surface antigen analysis by two-color flow cytometry. ( a ) Phenotype analysis of lymphocytes of the lymph node by flow cytometric analysis with a combination of anti-CD3/-CD20 and anti-CD27/-CD20 antibodies. B cells are surrounded by a dotted line. ( b ) Phenotype analysis of B cells purified using CD19-microbeads by flow cytomeric analysis with a combination of anti-CD3/-CD20 antibodies. Purified B cells are surrounded by a dotted line.

Article Snippet: B cells were purified using magnetic-activated cell sorting CD19 Micro Beads (Miltenyi Biotec, Auburn, CA, USA) according to the manufacturer’s instructions.

Techniques: Flow Cytometry, Purification

Characterization of the BiPSCs. ( a ) Immunofluorescence staining of BiPSC13 and MIB2-6 for expression of the pluripotent markers Oct3/4, Nanog, SSEA4, TRA-1-60, and TRA-1-81. ( b ) Expression of endogenous Oct3/4, Sox2, Klf4, cMyc, Pax5, AID , and GAPDH in BiPSCs (BiPSC13, MIB2-6) and normal B cells (CD19) from the lymph node analyzed using RT-PCR. ( c ) RT-PCR analysis of the expression of retrovirus-derived Oct3/4, Sox2, Klf4 , and cMyc in BiPSCs (BiPSC13, MIB2-6). HUC-Fm, human umbilical cord fibroblast cells, (male; RIKEN, Tsukuba, Japan) infected with a retrovirus containing Oct3/4 , Sox2 , Klf4 , c-Myc , and GAPDH for 5 days were used as the positive control.

Journal: Scientific Reports

Article Title: Establishment of induced pluripotent stem cells from normal B cells and inducing AID expression in their differentiation into hematopoietic progenitor cells

doi: 10.1038/s41598-017-01627-1

Figure Lengend Snippet: Characterization of the BiPSCs. ( a ) Immunofluorescence staining of BiPSC13 and MIB2-6 for expression of the pluripotent markers Oct3/4, Nanog, SSEA4, TRA-1-60, and TRA-1-81. ( b ) Expression of endogenous Oct3/4, Sox2, Klf4, cMyc, Pax5, AID , and GAPDH in BiPSCs (BiPSC13, MIB2-6) and normal B cells (CD19) from the lymph node analyzed using RT-PCR. ( c ) RT-PCR analysis of the expression of retrovirus-derived Oct3/4, Sox2, Klf4 , and cMyc in BiPSCs (BiPSC13, MIB2-6). HUC-Fm, human umbilical cord fibroblast cells, (male; RIKEN, Tsukuba, Japan) infected with a retrovirus containing Oct3/4 , Sox2 , Klf4 , c-Myc , and GAPDH for 5 days were used as the positive control.

Article Snippet: B cells were purified using magnetic-activated cell sorting CD19 Micro Beads (Miltenyi Biotec, Auburn, CA, USA) according to the manufacturer’s instructions.

Techniques: Immunofluorescence, Staining, Expressing, Reverse Transcription Polymerase Chain Reaction, Derivative Assay, Infection, Positive Control

AID expression in BiPSCs induced with the doxycycline-controlled (Tet-off) system. ( a ) Induction of AID expression in the absence of doxycycline was confirmed in two clones (#1 and #2) derived from BiPSC13 by western blotting, and ( b ) qRT-PCR. In ( b ), the numbers on the Y axis are the relative ratio comparing the expression of AID mRNA of each sample standardized by the expression of GAPDH mRNA with that of CD19 + normal B cells purified from normal LN using CD19-microbeads. Raji, Burkitt lymphoma cell line. Data were analyzed in triplicates and normalized to glyceraldehyde 3-phosphate dehydrogenase. ( c ) Immunofluorescence analysis of the expression of Oct3/4 and Nanog in BiPSC13-AID (#1 and #2) after the induction of AID expression in the absence of doxycycline. ( d ) Induction of AID expression in the absence of doxycycline in two clones (#16 and #17) derived from MIB2-6 by western blotting, and ( e ) qRT-PCR as described in the legend to ( b ). ( f ) Immunofluorescence analysis of the expression of Oct3/4 and Nanog in MIB-AID (#16 and #17) after the induction of AID expression in the absence of doxycycline.

Journal: Scientific Reports

Article Title: Establishment of induced pluripotent stem cells from normal B cells and inducing AID expression in their differentiation into hematopoietic progenitor cells

doi: 10.1038/s41598-017-01627-1

Figure Lengend Snippet: AID expression in BiPSCs induced with the doxycycline-controlled (Tet-off) system. ( a ) Induction of AID expression in the absence of doxycycline was confirmed in two clones (#1 and #2) derived from BiPSC13 by western blotting, and ( b ) qRT-PCR. In ( b ), the numbers on the Y axis are the relative ratio comparing the expression of AID mRNA of each sample standardized by the expression of GAPDH mRNA with that of CD19 + normal B cells purified from normal LN using CD19-microbeads. Raji, Burkitt lymphoma cell line. Data were analyzed in triplicates and normalized to glyceraldehyde 3-phosphate dehydrogenase. ( c ) Immunofluorescence analysis of the expression of Oct3/4 and Nanog in BiPSC13-AID (#1 and #2) after the induction of AID expression in the absence of doxycycline. ( d ) Induction of AID expression in the absence of doxycycline in two clones (#16 and #17) derived from MIB2-6 by western blotting, and ( e ) qRT-PCR as described in the legend to ( b ). ( f ) Immunofluorescence analysis of the expression of Oct3/4 and Nanog in MIB-AID (#16 and #17) after the induction of AID expression in the absence of doxycycline.

Article Snippet: B cells were purified using magnetic-activated cell sorting CD19 Micro Beads (Miltenyi Biotec, Auburn, CA, USA) according to the manufacturer’s instructions.

Techniques: Expressing, Clone Assay, Derivative Assay, Western Blot, Quantitative RT-PCR, Purification, Immunofluorescence