cardiac array Search Results


94
NeuroNexus Technologies pre assembled 16 channel silicon probe
Pre Assembled 16 Channel Silicon Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/Cardiac+array/bio_rxiv__2023__11__14__567066-242-15-22
Average 94 stars, based on 1 article reviews
pre assembled 16 channel silicon probe - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

94
Randox randox cardiac plus array
Randox Cardiac Plus Array, supplied by Randox, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/CARDIAC+ARRAY/10__4172_slash_2155___9880__1000600-3-45-45
Average 94 stars, based on 1 article reviews
randox cardiac plus array - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

96
Randox nphsii samples
Boxplot of gene score in UK healthy men and the <t>CoRDia</t> <t>SMI</t> plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, <t>NPHSII</t> n = 1360 and CoRDia plus risk results n = 66
Nphsii Samples, supplied by Randox, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/CARDIAC+RISK+PREDICTION+ARRAY/pmc05048451-100-10-23
Average 96 stars, based on 1 article reviews
nphsii samples - by Bioz Stars, 2026-09
96/100 stars
  Buy from Supplier

90
Siemens AG dedicated phased-array cardiac coil avanto
Boxplot of gene score in UK healthy men and the <t>CoRDia</t> <t>SMI</t> plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, <t>NPHSII</t> n = 1360 and CoRDia plus risk results n = 66
Dedicated Phased Array Cardiac Coil Avanto, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/phased+array+cardiac+coil/pmc04099275-110-10-16
Average 90 stars, based on 1 article reviews
dedicated phased-array cardiac coil avanto - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG 12-element phased array cardiac surface coil
Boxplot of gene score in UK healthy men and the <t>CoRDia</t> <t>SMI</t> plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, <t>NPHSII</t> n = 1360 and CoRDia plus risk results n = 66
12 Element Phased Array Cardiac Surface Coil, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/12+element+phased+array+cardiac+surface+coil/10__1161_slash_circimaging__115__004148-61-18-7
Average 90 stars, based on 1 article reviews
12-element phased array cardiac surface coil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG 3-t magnet with dedicated phased-array cardiac coil
Boxplot of gene score in UK healthy men and the <t>CoRDia</t> <t>SMI</t> plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, <t>NPHSII</t> n = 1360 and CoRDia plus risk results n = 66
3 T Magnet With Dedicated Phased Array Cardiac Coil, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/1+5+t+cardiac+phased+array+coil+wholebody+scanner/pmc10192280-88-6-17
Average 90 stars, based on 1 article reviews
3-t magnet with dedicated phased-array cardiac coil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Invivo Corporation 32-channel cardiac phased-array receiver coil
Boxplot of gene score in UK healthy men and the <t>CoRDia</t> <t>SMI</t> plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, <t>NPHSII</t> n = 1360 and CoRDia plus risk results n = 66
32 Channel Cardiac Phased Array Receiver Coil, supplied by Invivo Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/32+channel+cardiac+phased+array+receiver+coil/pmc05607067-114-3-6
Average 90 stars, based on 1 article reviews
32-channel cardiac phased-array receiver coil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Rapid Biomedical GmbH 8tx/16rx interface
Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an <t>8Tx/16Rx</t> array configuration
8tx/16rx Interface, supplied by Rapid Biomedical GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/8tx+16rx+ptx+transceiver+human+cardiac+array+prototype/pmc10140105-55-15-22
Average 90 stars, based on 1 article reviews
8tx/16rx interface - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Siemens AG gadolinium-enhanced cmri siemens magnetom sonata 1.5 t with phased-array cardiac-dedicated coil
Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an <t>8Tx/16Rx</t> array configuration
Gadolinium Enhanced Cmri Siemens Magnetom Sonata 1.5 T With Phased Array Cardiac Dedicated Coil, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/gadolinium+enhanced+cmri+siemens+magnetom+sonata+1+5+t+with+phased+array+cardiac+dedicated+coil/10__1161_slash_circimaging__112__979633-59-0-2
Average 90 stars, based on 1 article reviews
gadolinium-enhanced cmri siemens magnetom sonata 1.5 t with phased-array cardiac-dedicated coil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
MR Solutions 13 c four-channel cardiac receive array
Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an <t>8Tx/16Rx</t> array configuration
13 C Four Channel Cardiac Receive Array, supplied by MR Solutions, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/13+c+four+channel+cardiac+receive+array/pmc10386956-83-32-34
Average 90 stars, based on 1 article reviews
13 c four-channel cardiac receive array - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
SonoScape Medical Corp portable ultrasound machine sonoscape s2 with 2p1 4-2 mhz phased-array cardiac transducer
Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an <t>8Tx/16Rx</t> array configuration
Portable Ultrasound Machine Sonoscape S2 With 2p1 4 2 Mhz Phased Array Cardiac Transducer, supplied by SonoScape Medical Corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/portable+ultrasound+machine+sonoscape+s2+with+2p1+4+2+mhz+phased+array+cardiac+transducer/pm27445285-31-44-46
Average 90 stars, based on 1 article reviews
portable ultrasound machine sonoscape s2 with 2p1 4-2 mhz phased-array cardiac transducer - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
ATL Ultrasound Inc 64-element phased cardiac array p4-2
Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an <t>8Tx/16Rx</t> array configuration
64 Element Phased Cardiac Array P4 2, supplied by ATL Ultrasound Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cardiac+array/64+element+phased+cardiac+array+p4+2/pmc03908904-66-12-15
Average 90 stars, based on 1 article reviews
64-element phased cardiac array p4-2 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Boxplot of gene score in UK healthy men and the CoRDia SMI plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, NPHSII n = 1360 and CoRDia plus risk results n = 66

Journal: Cardiovascular Diabetology

Article Title: A 19-SNP coronary heart disease gene score profile in subjects with type 2 diabetes: the coronary heart disease risk in type 2 diabetes (CoRDia study) study baseline characteristics

doi: 10.1186/s12933-016-0457-7

Figure Lengend Snippet: Boxplot of gene score in UK healthy men and the CoRDia SMI plus risk results arm. The mean weighted gene score for each group is marked in red ( horizontal line represents the median) and these were compared using a t test (p = 0.80). Non-Caucasian participants were removed from the CoRDia SMI plus risk results profile group. The number of participants in each was as follows, NPHSII n = 1360 and CoRDia plus risk results n = 66

Article Snippet: Individuals in the CoRDia SMI + RR arm and selected NPHSII samples (n = 185) were genotyped using the Cardiac Risk Prediction Array (Randox Laboratories Ltd, Crumlin, Co Antrim, UK) according to the manufacturer’s instructions.

Techniques:

Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an 8Tx/16Rx array configuration

Journal: Magma (New York, N.y.)

Article Title: High-resolution imaging of the excised porcine heart at a whole-body 7 T MRI system using an 8Tx/16Rx pTx coil

doi: 10.1007/s10334-023-01077-z

Figure Lengend Snippet: Design and schematic of the ex-vivo array for high-resolution imaging of excised porcine hearts. a Coil elements layout, dimensions, and element numbering. b RF simulation model of the array loaded with a 10-cm spherical phantom in front, top, and side views. c A prototype of the 16-element antisymmetric array in the top, bottom, and side views. Phase shifters (PS) and cable traps (CT) are labeled accordingly. Every two neighboring loops are paired to be interfaced to the corresponding Tx channel of RFPA (channel numbering is according to the MRI system notation) to form an 8Tx/16Rx array configuration

Article Snippet: The complete pairing list is shown in Fig. c. The array was connected to the 8Tx/16Rx interface with 16-Tx/Rx switches and 16-preamplifiers (Rapid Biomedical GmbH, Rimpar, Germany) via four plugs (ODU GmbH & Co. KG, Mühldorf a. Inn, Germany).

Techniques: Ex Vivo, Imaging, Labeling