auto40 Search Results


90
Apogee Flow Systems Ltd flow cytometer auto40
Gating strategy for the volumetric <t>Auto40</t> flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK), as depicted from typical figure provided by “Auto-Lymphocyte” software (Apogee Flow Systems Ltd) for the counting of CD4 T lymphocytes in one K 3 -EDTA-anticoagulated blood sample, incubated with phycoerythrin (PE)-conjugated anti-CD4 and PE-Dyomics649-conjugated anti-CD45 monoclonal antibodies (Apogee Flow Systems Ltd): (A) CD45-PE-Dyomics649 × axis-light scatter dot plot scattergram; the primary CD45 gating differentiates clearly the CD45-positive lymphocytes and monocyte populations, and the population of polymorphonuclear cells; (B) CD4-PE × axis-light scatter dot plot scattergram; double secondary CD4 gating allows counting independently the population of CD4-negative lymphocyte and CD4-positive lymphocytes; the CD4 T lymphocytes count in absolute number is given by the CD4-positive gating; the CD4 T lymphocytes count in percentage corresponds to the ratio of CD4-positive lymphocytes count in absolute number to the total CD4-postive and CD4-negative lymphocytes counts, corresponding to the sum of both secondary gating.
Flow Cytometer Auto40, supplied by Apogee Flow Systems Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/flow cytometer auto40/product/Apogee Flow Systems Ltd
Average 90 stars, based on 1 article reviews
flow cytometer auto40 - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Gating strategy for the volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK), as depicted from typical figure provided by “Auto-Lymphocyte” software (Apogee Flow Systems Ltd) for the counting of CD4 T lymphocytes in one K 3 -EDTA-anticoagulated blood sample, incubated with phycoerythrin (PE)-conjugated anti-CD4 and PE-Dyomics649-conjugated anti-CD45 monoclonal antibodies (Apogee Flow Systems Ltd): (A) CD45-PE-Dyomics649 × axis-light scatter dot plot scattergram; the primary CD45 gating differentiates clearly the CD45-positive lymphocytes and monocyte populations, and the population of polymorphonuclear cells; (B) CD4-PE × axis-light scatter dot plot scattergram; double secondary CD4 gating allows counting independently the population of CD4-negative lymphocyte and CD4-positive lymphocytes; the CD4 T lymphocytes count in absolute number is given by the CD4-positive gating; the CD4 T lymphocytes count in percentage corresponds to the ratio of CD4-positive lymphocytes count in absolute number to the total CD4-postive and CD4-negative lymphocytes counts, corresponding to the sum of both secondary gating.

Journal: BMC Health Services Research

Article Title: Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry

doi: 10.1186/1472-6963-13-373

Figure Lengend Snippet: Gating strategy for the volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK), as depicted from typical figure provided by “Auto-Lymphocyte” software (Apogee Flow Systems Ltd) for the counting of CD4 T lymphocytes in one K 3 -EDTA-anticoagulated blood sample, incubated with phycoerythrin (PE)-conjugated anti-CD4 and PE-Dyomics649-conjugated anti-CD45 monoclonal antibodies (Apogee Flow Systems Ltd): (A) CD45-PE-Dyomics649 × axis-light scatter dot plot scattergram; the primary CD45 gating differentiates clearly the CD45-positive lymphocytes and monocyte populations, and the population of polymorphonuclear cells; (B) CD4-PE × axis-light scatter dot plot scattergram; double secondary CD4 gating allows counting independently the population of CD4-negative lymphocyte and CD4-positive lymphocytes; the CD4 T lymphocytes count in absolute number is given by the CD4-positive gating; the CD4 T lymphocytes count in percentage corresponds to the ratio of CD4-positive lymphocytes count in absolute number to the total CD4-postive and CD4-negative lymphocytes counts, corresponding to the sum of both secondary gating.

Article Snippet: We herein addressed the principal issues raised by the implementation of the single-platform, volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) in 8 community HIV monitoring laboratories of different levels throughout Chad.

Techniques: Flow Cytometry, Software, Incubation, Bioprocessing

Map showing the location of the 22 officially approved health care centers devoted to follow up adult and children patients infected with HIV-1 thorough Chad in 2013 (Am Timane, Abeche, Adre, Ati, Biltine, Bol, Bongor, Doba, Fada, Faya-Largeau, Gos Beïda, Kelo, Koumra, Lere, Maïssala, Mao, Mongo, Moundou, N’Djamena, Ngouri, Pala and Sahr), as well as the 8 centers equipped by the Auto40 flow cytometers (Apogee Flow Systems Ltd) (2 in N’Djamena at the hôpital Militaire D’Instruction, and the Centre D’Appui Psycho-Médico-Social Al-Nadjma; 1 in Mongo, Bongor, Doba, Kelo, Koumra and Maïssala), and the other 9 centers equipped by FACSCount (Becton Dickinson) (2 in N’Djamena; 1 in Abeche, Adre, Gos Beïda, Moundou, Pala and Sahr), or by CyFlow (Partec) (Adre, Biltine, Maïssala, Mao and Ngouri). Note that 5 health care centers for HIV-1-infected patients (Ati; Bol; Fada; Faya-Largeau; Lere) are not yet equipped for CD4 T cell enumeration. The reference laboratory of the hôpital de la Liberté, N’Djamena, is equipped by FACSCalibur (Becton Dickinson). Note that only the health care centers involved in caring HIV-infected patients are shown in the map.

Journal: BMC Health Services Research

Article Title: Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry

doi: 10.1186/1472-6963-13-373

Figure Lengend Snippet: Map showing the location of the 22 officially approved health care centers devoted to follow up adult and children patients infected with HIV-1 thorough Chad in 2013 (Am Timane, Abeche, Adre, Ati, Biltine, Bol, Bongor, Doba, Fada, Faya-Largeau, Gos Beïda, Kelo, Koumra, Lere, Maïssala, Mao, Mongo, Moundou, N’Djamena, Ngouri, Pala and Sahr), as well as the 8 centers equipped by the Auto40 flow cytometers (Apogee Flow Systems Ltd) (2 in N’Djamena at the hôpital Militaire D’Instruction, and the Centre D’Appui Psycho-Médico-Social Al-Nadjma; 1 in Mongo, Bongor, Doba, Kelo, Koumra and Maïssala), and the other 9 centers equipped by FACSCount (Becton Dickinson) (2 in N’Djamena; 1 in Abeche, Adre, Gos Beïda, Moundou, Pala and Sahr), or by CyFlow (Partec) (Adre, Biltine, Maïssala, Mao and Ngouri). Note that 5 health care centers for HIV-1-infected patients (Ati; Bol; Fada; Faya-Largeau; Lere) are not yet equipped for CD4 T cell enumeration. The reference laboratory of the hôpital de la Liberté, N’Djamena, is equipped by FACSCalibur (Becton Dickinson). Note that only the health care centers involved in caring HIV-infected patients are shown in the map.

Article Snippet: We herein addressed the principal issues raised by the implementation of the single-platform, volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) in 8 community HIV monitoring laboratories of different levels throughout Chad.

Techniques: Infection

Main characteristics describing the implementation and the 5 years usage (2008–2013) of 8 single-platform,  volumetric, Auto40 flow  cytometers for community-based point-of-care CD4 T lymphocytes enumeration installed in Chad

Journal: BMC Health Services Research

Article Title: Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry

doi: 10.1186/1472-6963-13-373

Figure Lengend Snippet: Main characteristics describing the implementation and the 5 years usage (2008–2013) of 8 single-platform, volumetric, Auto40 flow cytometers for community-based point-of-care CD4 T lymphocytes enumeration installed in Chad

Article Snippet: We herein addressed the principal issues raised by the implementation of the single-platform, volumetric Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) in 8 community HIV monitoring laboratories of different levels throughout Chad.

Techniques: Activity Assay, Cell Counting, Control