Arthrex Inc
arthroscopic shaver arthrex ![]() Arthroscopic Shaver Arthrex, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+arthrex/pmc12177371-25-16-18 Average 90 stars, based on 1 article reviews
arthroscopic shaver arthrex - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
curved arthroscopic shaver 30° angled double-bite ![]() Curved Arthroscopic Shaver 30° Angled Double Bite, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/curved+arthroscopic+shaver+30++angled+double+bite/pmc04811202-62-1-9 Average 90 stars, based on 1 article reviews
curved arthroscopic shaver 30° angled double-bite - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
3.5-mm arthroscopic shaver ![]() 3.5 Mm Arthroscopic Shaver, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/3+5+mm+arthroscopic+shaver/pmc09561677-106-20-22 Average 90 stars, based on 1 article reviews
3.5-mm arthroscopic shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
arthroscopic shaver stryker ![]() Arthroscopic Shaver Stryker, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+stryker/pmc07735384-81-1-3 Average 90 stars, based on 1 article reviews
arthroscopic shaver stryker - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Arthrex Inc
arthroscopic torpedo shaver ![]() Arthroscopic Torpedo Shaver, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+torpedo/pmc07953262-17-1-4 Average 90 stars, based on 1 article reviews
arthroscopic torpedo shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
arthroscopic shaver aggressive plus cutter ![]() Arthroscopic Shaver Aggressive Plus Cutter, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+aggressive+plus+cutter/pmc05442417-95-21-26 Average 90 stars, based on 1 article reviews
arthroscopic shaver aggressive plus cutter - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
full radius arthroscopic shaver Full Radius Arthroscopic Shaver, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver/pmc08252822-30-5-9 Average 90 stars, based on 1 article reviews
full radius arthroscopic shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Smith & Nephew
4.5-mm-diameter arthroscopic shaver 4.5 Mm Diameter Arthroscopic Shaver, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver/pmc05368053-34-54-57 Average 90 stars, based on 1 article reviews
4.5-mm-diameter arthroscopic shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Arthrex Inc
arthroscope shaver Arthroscope Shaver, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver/pm40329219-50-23-32 Average 90 stars, based on 1 article reviews
arthroscope shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Joimax Inc
arthroscopic shavers Arthroscopic Shavers, supplied by Joimax Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shavers/pm39952432-65-2-3 Average 90 stars, based on 1 article reviews
arthroscopic shavers - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Arthrex Inc
arthroscopic shaver synergy resection shaver console and aps ii handpiece ![]() Arthroscopic Shaver Synergy Resection Shaver Console And Aps Ii Handpiece, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+synergy+resection+shaver+console+and+aps+ii+handpiece/pmc04908272-58-14-24 Average 90 stars, based on 1 article reviews
arthroscopic shaver synergy resection shaver console and aps ii handpiece - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Stryker
arthroscopic shaver formula shaver ![]() Arthroscopic Shaver Formula Shaver, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/arthroscopic+shaver/arthroscopic+shaver+formula+shaver/pm38402631-61-1-5 Average 90 stars, based on 1 article reviews
arthroscopic shaver formula shaver - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Arthroscopy Techniques
Article Title: Reconstruction of the Medial Patellofemoral Ligament Through a Double Bundle of a Single Patellar Tract and Quadriceps Tendon: A Modified Technique
doi: 10.1016/j.eats.2024.103361
Figure Lengend Snippet: Arthroscopic view of prolapsed patella and femoral trochlear groove.
Article Snippet: A probe is used to exclude anterior and posterior cruciate ligament and meniscal injuries, and an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Reconstruction of the Medial Patellofemoral Ligament Through a Double Bundle of a Single Patellar Tract and Quadriceps Tendon: A Modified Technique
doi: 10.1016/j.eats.2024.103361
Figure Lengend Snippet: A left knee is shown. (A) Kirschner wire-guided drilling of the femoral tunnel is performed along the direction of the red arrow. (B) Tissue forceps are used to pass through the arthroscopic capsule of the medial retinaculum of the knee, that is, the superficial layer of the medial collateral ligament, to prepare to grab the graft (black arrow) back to the medial side (yellow arrow). (C) The Kirschner wire guides the graft through the femoral tunnel (green arrow).
Article Snippet: A probe is used to exclude anterior and posterior cruciate ligament and meniscal injuries, and an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Reconstruction of the Medial Patellofemoral Ligament Through a Double Bundle of a Single Patellar Tract and Quadriceps Tendon: A Modified Technique
doi: 10.1016/j.eats.2024.103361
Figure Lengend Snippet: Arthroscopic examination showing that the patellofemoral joint is well aligned and the graft does not enter the joint cavity.
Article Snippet: A probe is used to exclude anterior and posterior cruciate ligament and meniscal injuries, and an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Bone Grafting of Deep Acetabular Cysts Using a Curved Delivery Device
doi: 10.1016/j.eats.2015.10.012
Figure Lengend Snippet: Intraoperative arthroscopic images corresponding to the right hip in Figure 1. (A) Viewing through the mid-trochanteric portal with a 30° arthroscope, the full-thickness articular cartilage flap (black asterisk) is gently elevated with a probe (yellow asterisk) inserted through the mid-anterior portal. The articular cartilage flap covers the underlying acetabular bone cyst. (B) Viewing through the mid-anterior portal with a 30° arthroscope, an angled curette (yellow asterisk) is inserted through the mid-trochanteric portal to remove the calcified cartilage layer from the articular cartilage defect and to establish a stable rim. The articular communication of the cystic contents (black asterisk) is seen adjacent to the curette. (C) Viewing through the mid-trochanteric portal with a 30° arthroscope, the well-contained articular cartilage defect is seen (black asterisk) after removal of the overlying full-thickness cartilage flap. (D) Viewing through the mid-trochanteric portal with a 30° arthroscope, an angled microfracture awl (yellow asterisk) is inserted through the mid-anterior portal to gently probe and excavate the mucinous contents from the cystic cavity, adjacent to the articular cartilage defect (black asterisk). (a, acetabulum; CF, cotyloid fossa.)
Article Snippet: A
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Bone Grafting of Deep Acetabular Cysts Using a Curved Delivery Device
doi: 10.1016/j.eats.2015.10.012
Figure Lengend Snippet: Sheath disassembly and intraoperative arthroscopic images corresponding to the right hip in Figure 1. (A) The curved shaver is disassembled by applying pressure against the sterile back table until the angle of curvature is slightly reduced. This allows the inner sleeve (blue) to be removed from the outer sheath (red) with relative ease. (B) The outer sheath is loaded with bone graft (BG), and the inner sleeve is used as a plunger until the bone graft can be seen exiting the side-opening. The outer sheath may then be manipulated against the back table to the desired degree of curvature before inserting into the joint for bone graft application. (C) Viewing through the mid-trochanteric portal with a 30° arthroscope, a curved shaver sleeve (yellow asterisk) loaded with bone graft is inserted through the mid-anterior portal in preparation for bone grafting of the cystic cavities (white asterisks). (D) Viewing through the mid-trochanteric portal with a 30° arthroscope, a curved shaver sleeve (yellow asterisk) is placed with the side-opening of the shaver sleeve facing the cystic cavity to deliver the bone graft. Air bubbles are seen as the inner sleeve of the curved shaver is deployed as a plunger to deliver the bone graft and pressurize the cystic cavity. (E) Viewing through the mid-anterior portal with a 30° arthroscope, a well-positioned bone graft can be seen within the loculated cystic cavity in the well-contained articular cartilage defect. (a, acetabulum; L, labrum.)
Article Snippet: A
Techniques: Sterility
Journal: Orthopaedic Journal of Sports Medicine
Article Title: Chronic Lateral Ankle Instability Treated With Tendon Allografting: A Preliminary Comparison of Arthroscopic and Open Anatomic Ligament Reconstruction
doi: 10.1177/23259671221126693
Figure Lengend Snippet: Demographic Characteristics Within the Arthroscopic and Open Reconstruction Groups a
Article Snippet: Subsequently, the viewing portal was changed to the ST portal, and the residual CFL stump was debrided using a 3.5-mm
Techniques: Control
Journal: Orthopaedic Journal of Sports Medicine
Article Title: Chronic Lateral Ankle Instability Treated With Tendon Allografting: A Preliminary Comparison of Arthroscopic and Open Anatomic Ligament Reconstruction
doi: 10.1177/23259671221126693
Figure Lengend Snippet: Dynamic ultrasound examination in patient 2 of the arthroscopic group. (A) In the ankle neutral position, the ultrasound revealed a 5.92-mm hypoechoic gap with a residual distal ATFL stump connected to the lateral talus (LT). (B) In the ankle plantarflexion-inversion position, a movable bony fragment was observed that was pulled distally by the residual inferior bundle of the ATFL stump. The gap between the fibular tip and distal ATFL stump including the avulsed bony fragment and hypoechoic ligament tear part was 10.97 mm, indicating that the repair of lesions is difficult owing to the presence of insufficient residual ligament tissue. ATFL, anterior talofibular ligament; DF, distal fibula.
Article Snippet: Subsequently, the viewing portal was changed to the ST portal, and the residual CFL stump was debrided using a 3.5-mm
Techniques:
Journal: Orthopaedic Journal of Sports Medicine
Article Title: Chronic Lateral Ankle Instability Treated With Tendon Allografting: A Preliminary Comparison of Arthroscopic and Open Anatomic Ligament Reconstruction
doi: 10.1177/23259671221126693
Figure Lengend Snippet: Comparison of Outcome Scores Between Preoperatively and 2 Years Postoperatively in the Arthroscopic and Open Groups a
Article Snippet: Subsequently, the viewing portal was changed to the ST portal, and the residual CFL stump was debrided using a 3.5-mm
Techniques: Comparison
Journal: Orthopaedic Journal of Sports Medicine
Article Title: Chronic Lateral Ankle Instability Treated With Tendon Allografting: A Preliminary Comparison of Arthroscopic and Open Anatomic Ligament Reconstruction
doi: 10.1177/23259671221126693
Figure Lengend Snippet: Comparison of 2-Year Postoperative Outcome Scores Between the Arthroscopic and Open Groups a
Article Snippet: Subsequently, the viewing portal was changed to the ST portal, and the residual CFL stump was debrided using a 3.5-mm
Techniques: Comparison
Journal: Orthopaedic Journal of Sports Medicine
Article Title: Chronic Lateral Ankle Instability Treated With Tendon Allografting: A Preliminary Comparison of Arthroscopic and Open Anatomic Ligament Reconstruction
doi: 10.1177/23259671221126693
Figure Lengend Snippet: Postoperative Complications a
Article Snippet: Subsequently, the viewing portal was changed to the ST portal, and the residual CFL stump was debrided using a 3.5-mm
Techniques: Infection
Journal: Journal of orthopaedic research : official publication of the Orthopaedic Research Society
Article Title: Transection of the Medial Meniscus Anterior Horn Results in Cartilage Degeneration and Meniscus Remodeling in a Large Animal Model
doi: 10.1002/jor.24694
Figure Lengend Snippet: A) Juvenile Yucatan minipigs (6 months) underwent bilateral hindlimb surgery and received B) Sham or DMM surgical procedures. A = anterior, P = posterior, M = medial, L = lateral. C) Pre-operative image showing joint markings to aid in portal placement. D) Intraoperative image showing locations of lateral and medial portals, and E) arthroscopic camera and probe locations. F) Intra-arthroscopy movie of DMM procedure and G) still images immediately prior to DMM procedure and H) after severing the anterior attachment. I) Timeline of outcome measures post-euthanasia.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating the full-thickness radial tear evaluated with probing.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating an arthroscopic torpedo shaver (Arthrex, Naples, FL, U.S.A.) used to debride the meniscus tear edges back to a healthy, stable rim.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating the inside-out needle Meniscal Zone Navigator (Arthrex, Naples, FL, U.S.A.) placed through the anterolateral portal. Sutures were then passed from outside in on either side of the radial tear.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating 2 vertical mattress sutures using No. 0 fiberwire nonabsorbable suture, each passed with one on each leaflet of the tear approximately 2 to 3 mm from the tear edge to serve as rip stops for bridging sutures across the tear.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating the ripstop configuration was used where one suture was placed on either end of the tear and then oblique mattress-style sutures are placed on either side of the rip stop. After these 14 inside-out meniscal sutures were tied, 2 additional sutures were placed inside out and passed obliquely, one on the anterior portion of the meniscus and the other on the posterior side for use as shuttling sutures.
Article Snippet: An
Techniques:
Journal: Arthroscopy Techniques
Article Title: Full-Thickness Radial Medial Meniscal Tear: Fixation With Inside-Out Technique With Tibial Knotless Suture Anchors
doi: 10.1016/j.eats.2020.10.075
Figure Lengend Snippet: A 30-degree arthroscopic image of a right knee while viewing through an anteromedial portal demonstrating the final construct after the 14 meniscal sutures were tied and the meniscus was repaired to the tibia with the use of 2 suture anchors.
Article Snippet: An
Techniques: Construct
Journal: Arthroscopy Techniques
Article Title: Management of the Stiff Shoulder With Arthroscopic Circumferential Capsulotomy and Axillary Nerve Release
doi: 10.1016/j.eats.2016.10.005
Figure Lengend Snippet: Advantages and Risks of Arthroscopic Circumferential Capsulotomy
Article Snippet: In cases in which osteophytes or synovitis makes visualization of the underlying capsule difficult, these tissues are removed with a 4.0-mm
Techniques: Dissection, Disruption
Journal: Arthroscopy Techniques
Article Title: Management of the Stiff Shoulder With Arthroscopic Circumferential Capsulotomy and Axillary Nerve Release
doi: 10.1016/j.eats.2016.10.005
Figure Lengend Snippet: Specific Instrumentation Needed for Complete Arthroscopic Circumferential Capsulotomy Procedure
Article Snippet: In cases in which osteophytes or synovitis makes visualization of the underlying capsule difficult, these tissues are removed with a 4.0-mm
Techniques:
Journal: Arthroscopy Techniques
Article Title: Management of the Stiff Shoulder With Arthroscopic Circumferential Capsulotomy and Axillary Nerve Release
doi: 10.1016/j.eats.2016.10.005
Figure Lengend Snippet: Initial arthroscopic visualization of stiff shoulder. (A) We begin by using a posterior viewing portal; synovitis and adhesions are shown. (B) The superior capsule is released from the superior labrum/biceps anchor. (C) We then transition to viewing anteriorly and working posteriorly with an up-biting duckbill basket (asterisk) through the aforementioned posterior portal. This instrument is used bluntly initially to separate the capsule and is then used as a biter to divide it superiorly to the prior level of release and inferiorly to the axillary pouch. (D) Once the capsule has been fully released posteriorly, the muscle belly of the infraspinatus should be readily visible.
Article Snippet: In cases in which osteophytes or synovitis makes visualization of the underlying capsule difficult, these tissues are removed with a 4.0-mm
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Anchor-Based Hip Capsular Reconstruction Without Graft Augmentation
doi: 10.1016/j.eats.2021.02.018
Figure Lengend Snippet: This video demonstrates our preferred technique for arthroscopic capsular reconstruction with acetabular sided anchors for patients undergoing revision hip arthroscopy for capsular insufficiency. Before proceeding with this technique, it is essential to treat any other pathology in the central and peripheral compartment of the hip and ensure adequate capsular reduction to the acetabular rim to determine feasibility of repair.
Article Snippet: At this point, a 4.0-mm full radius arthroscopic shaver (Stryker) is used to demarcate the plain between the capsule and the labrum, followed by radiofrequency ablation as needed to further develop this interval.
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Anchor-Based Hip Capsular Reconstruction Without Graft Augmentation
doi: 10.1016/j.eats.2021.02.018
Figure Lengend Snippet: View of a right hip from the modified mid-anterior portal with 70° arthroscope. Arthroscopic grasper is used to assess the mobility of the femoral-sided capsular leaflet (C). (F, femoral head.)
Article Snippet: At this point, a 4.0-mm full radius arthroscopic shaver (Stryker) is used to demarcate the plain between the capsule and the labrum, followed by radiofrequency ablation as needed to further develop this interval.
Techniques: Modification
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view through the anterolateral portal in a left shoulder in the modified beach-chair position. An extensive glenohumeral debridement with lysis of adhesions around the rotator cuff tendon is performed to mobilize the tendon.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques: Modification, Lysis
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view from the posterolateral portal in a left shoulder in the modified beach-chair position. A massive tear of the rotator cuff is visualized.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques: Modification
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view through the posterolateral portal in a left shoulder. The 4.75-mm BioComposite SwiveLock anchor loaded with FiberTape is placed 1 to 2 mm adjacent to the articular cartilage margin of the humeral head.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view through the anterolateral portal in a left shoulder showing placement of the posteromedial suture anchor.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view through the posterolateral portal in a left shoulder. The rotator cuff tendon is grasped, and a suture lasso is used to shuttle the FiberTape sutures back through the tendon. It is important to pass the sutures lateral to the musculotendinous junction to avoid damage.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view through the posterolateral portal in a left shoulder. The FiberTapes are tensioned through the eyelet of the SwiveLock anchors. This compresses the rotator cuff down to the footprint. The anterolateral anchor is placed first in the lateral row, followed by the posterolateral anchor. Working from outside in helps avoid the formation of dog ears.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques:
Journal: Arthroscopy Techniques
Article Title: Arthroscopic Knotless, Double-Row, Extended Linked Repair for Massive Rotator Cuff Tears
doi: 10.1016/j.eats.2015.10.007
Figure Lengend Snippet: Arthroscopic view from the anterolateral portal in a left shoulder that is positioned in the modified beach-chair position. The final low-profile, extended linked, double-row repair construct is visualized.
Article Snippet: The footprint on the greater tuberosity is debrided to a bleeding surface with an
Techniques: Modification, Construct