3d electroanatomical mapping eam system Search Results


86
Boston Scientific Corporation 3d electroanatomic mapping systems
3d Electroanatomic Mapping Systems, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/mapping+rhythmia+system/pm41712165-49-4-29
Average 86 stars, based on 1 article reviews
3d electroanatomic mapping systems - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Biosense Webster 3d electroanatomical mapping system carto
3d Electroanatomical Mapping System Carto, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/electroanatomic+mapping+system+carto/pmc10740977-120-3-10
Average 90 stars, based on 1 article reviews
3d electroanatomical mapping system carto - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster pentaray
Pentaray, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/pentaray+catheter/pm36319975-46-45-48
Average 90 stars, based on 1 article reviews
pentaray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster carto
Carto, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/carto/pmc03651513-112-24-29
Average 90 stars, based on 1 article reviews
carto - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster electroanatomical 3d-mapping system carto® 3 system
Electroanatomical 3d Mapping System Carto® 3 System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/3d+mapping+system/pmc09160260-75-7-13
Average 90 stars, based on 1 article reviews
electroanatomical 3d-mapping system carto® 3 system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
St Jude Medical 3d electroanatomical mapping navx
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
3d Electroanatomical Mapping Navx, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/ensite+navx+system/pmc05447124-17-13-17
Average 90 stars, based on 1 article reviews
3d electroanatomical mapping navx - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
St Jude Medical navx
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
Navx, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/navx/pm31753429-65-27-32
Average 90 stars, based on 1 article reviews
navx - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation 3d electroanatomical mapping system
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
3d Electroanatomical Mapping System, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/electroanatomical+mapping+system/pm32564870-36-1-23
Average 90 stars, based on 1 article reviews
3d electroanatomical mapping system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Abbott Laboratories navx electroanatomic 3d mapping system ensite
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
Navx Electroanatomic 3d Mapping System Ensite, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/ensite+precision+mapping+system/pm31650456-16-12-21
Average 90 stars, based on 1 article reviews
navx electroanatomic 3d mapping system ensite - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Abbott Laboratories navx electroanatomic 3-d mapping system precision
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
Navx Electroanatomic 3 D Mapping System Precision, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/electroanatomic+mapping+system+ensite+navx/pm31650456-40-12-22
Average 90 stars, based on 1 article reviews
navx electroanatomic 3-d mapping system precision - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
St Jude Medical 3d electroanatomical mapping system
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
3d Electroanatomical Mapping System, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/3d+electroanatomical+mapping+system/10__1155_slash_2024_slash_1087623-46-6-11
Average 86 stars, based on 1 article reviews
3d electroanatomical mapping system - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Biosense Webster 3 d electroanatomical mapping
Three-dimensional <t>(3D)</t> activation map (A). The focal pattern of activation is demonstrated using <t>electroanatomical</t> mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).
3 D Electroanatomical Mapping, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+electroanatomical+mapping+eam+system/electroanatomical+mapping+system/10__1253_slash_circj__cj___14___0823-30-2-7
Average 86 stars, based on 1 article reviews
3 d electroanatomical mapping - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Three-dimensional (3D) activation map (A). The focal pattern of activation is demonstrated using electroanatomical mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).

Journal: Yonsei Medical Journal

Article Title: Focal Atrial Tachycardia Arising from the Inferior Vena Cava

doi: 10.3349/ymj.2017.58.4.884

Figure Lengend Snippet: Three-dimensional (3D) activation map (A). The focal pattern of activation is demonstrated using electroanatomical mapping. The earliest activation site of the tachycardia near the junction between the inferior vena cava (IVC) and right atrium (RA) is shown on the anatomical reconstruction of the RA. The area in white represents the earliest activation region during initiation of the propagation sequence. 3D voltage map (B). Endocardial voltage mapping in the RA is demonstrated. The voltage amplitudes of the sample points (small yellow dots) are assessed, and the points are set to a color scale as indicated in the figure. Large, irregular regions of extremely low voltage (red) consistent with myocardial scarring can be detected over the entire RA. Fluoroscopic projections showing the intracardiac positions of the ablation catheter (C). The catheter ablation site located in the IVC-RA junction is presented in the left anterior oblique view (LAO) and right anterior oblique view (RAO).

Article Snippet: Although focal ectopic AT was suspected as the mechanism, we mapped AT with 3D electroanatomical mapping (NavX, St. Jude Medical, St. Paul, MN, USA) because the patient had a history of cardiac surgery.

Techniques: Activation Assay, Sequencing