3d convolution model Search Results


90
Leeman Labs 3d convolution model
(Color online) Model of <t>3D</t> <t>convolution</t> of a pulse with the fractal branching cylindrical fluid-filled channels in a soft tissue.
3d Convolution Model, supplied by Leeman Labs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+convolution+model/3d+convolution+model/pmc06853797-49-220-226
Average 90 stars, based on 1 article reviews
3d convolution model - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Autodesk Inc 3d model of a convoluted pmi chip
The configuration of a physiodynamic mucosal interface-on-a-chip (PMI Chip). ( A ) A photograph of a PMI Chip device. The culture medium was filled in the upper and lower microchannels to visualize <t>the</t> <t>convoluted</t> design of microchannels. ( B ) A <t>3D</t> layout of a PMI Chip and a zoom-in cross-sectional view illustrate the structural configuration of the convoluted microchannel that contains an organoid-derived 3D epithelial layer. The upper (blue) and lower (red) microchannels mimic the lumen and capillary compartments in the gut, respectively. ( C ) The cross-sectional micrographs of a PMI Chip (upper panel) and the zoom-in insets (lower panel) that highlight the white dashed boxes in the upper panel. An inset in the lower right panel shows a cross-cut view of a PDMS porous membrane (Bar, 50 μm). V, vacuum chamber; U, upper microchannel; L, lower microchannel. ( D ) The velocity profiles of fluid flow (unit, μm/s) in the upper and lower microchannels at 50 μL/h. White arrows in the zoom-in insets indicate the direction of the fluid flow and the magnitude of a linear flow rate.
3d Model Of A Convoluted Pmi Chip, supplied by Autodesk Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+convolution+model/3d+model+of+a+convoluted+pmi+chip/pmc07408321-27-1-12
Average 90 stars, based on 1 article reviews
3d model of a convoluted pmi chip - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Haiying Enterprise Group Co Ltd 3d convolutional neural network model
The configuration of a physiodynamic mucosal interface-on-a-chip (PMI Chip). ( A ) A photograph of a PMI Chip device. The culture medium was filled in the upper and lower microchannels to visualize <t>the</t> <t>convoluted</t> design of microchannels. ( B ) A <t>3D</t> layout of a PMI Chip and a zoom-in cross-sectional view illustrate the structural configuration of the convoluted microchannel that contains an organoid-derived 3D epithelial layer. The upper (blue) and lower (red) microchannels mimic the lumen and capillary compartments in the gut, respectively. ( C ) The cross-sectional micrographs of a PMI Chip (upper panel) and the zoom-in insets (lower panel) that highlight the white dashed boxes in the upper panel. An inset in the lower right panel shows a cross-cut view of a PDMS porous membrane (Bar, 50 μm). V, vacuum chamber; U, upper microchannel; L, lower microchannel. ( D ) The velocity profiles of fluid flow (unit, μm/s) in the upper and lower microchannels at 50 μL/h. White arrows in the zoom-in insets indicate the direction of the fluid flow and the magnitude of a linear flow rate.
3d Convolutional Neural Network Model, supplied by Haiying Enterprise Group Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+convolution+model/3d+convolutional+neural+network+model/10__1016_slash_j__aiig__2024__100092-7-1-22
Average 90 stars, based on 1 article reviews
3d convolutional neural network model - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


(Color online) Model of 3D convolution of a pulse with the fractal branching cylindrical fluid-filled channels in a soft tissue.

Journal: The Journal of the Acoustical Society of America

Article Title: The first order statistics of backscatter from the fractal branching vasculature

doi: 10.1121/1.5132934

Figure Lengend Snippet: (Color online) Model of 3D convolution of a pulse with the fractal branching cylindrical fluid-filled channels in a soft tissue.

Article Snippet: Thus, assuming an optimal alignment, the 3D convolution result is given by the product of the transforms, D 3 I { echo ( x , y , z , t = 0 ) } = I 3 D { p ( x , y , z ) } · ( k x ) 2 I 3 D { cylinder ( x , y , z ) } = ( ( 4 e − k x 2 π 2 σ x 2 k x 2 π 5 / 2 σ x 3 ) ( e − 2 k y 2 π 2 σ y 2 2 π σ y ) ( e − 2 k z 2 π 2 σ z 2 2 π σ z ) ) · ( k x ) 2 κ 0 ( a [ 1 k x 2 + k y 2 ] · ( J 1 [ 2 a π k x 2 + k y 2 ] ) ) δ [ k z ] , (5) where t = 0 is assigned to the central peak of the echo, and the ( k x ) 2 term pre-multiplying the cylinder transform stems from the Laplacian spatial derivative in the Born scattering formulation ( Rayleigh, 1918a ; Morse and Ingard, 1987 ) and in the 3D convolution model ( Gore and Leeman, 1977 ; Bamber and Dickinson, 1980 ).

Techniques:

The configuration of a physiodynamic mucosal interface-on-a-chip (PMI Chip). ( A ) A photograph of a PMI Chip device. The culture medium was filled in the upper and lower microchannels to visualize the convoluted design of microchannels. ( B ) A 3D layout of a PMI Chip and a zoom-in cross-sectional view illustrate the structural configuration of the convoluted microchannel that contains an organoid-derived 3D epithelial layer. The upper (blue) and lower (red) microchannels mimic the lumen and capillary compartments in the gut, respectively. ( C ) The cross-sectional micrographs of a PMI Chip (upper panel) and the zoom-in insets (lower panel) that highlight the white dashed boxes in the upper panel. An inset in the lower right panel shows a cross-cut view of a PDMS porous membrane (Bar, 50 μm). V, vacuum chamber; U, upper microchannel; L, lower microchannel. ( D ) The velocity profiles of fluid flow (unit, μm/s) in the upper and lower microchannels at 50 μL/h. White arrows in the zoom-in insets indicate the direction of the fluid flow and the magnitude of a linear flow rate.

Journal: Micromachines

Article Title: Three-Dimensional Regeneration of Patient-Derived Intestinal Organoid Epithelium in a Physiodynamic Mucosal Interface-on-a-Chip

doi: 10.3390/mi11070663

Figure Lengend Snippet: The configuration of a physiodynamic mucosal interface-on-a-chip (PMI Chip). ( A ) A photograph of a PMI Chip device. The culture medium was filled in the upper and lower microchannels to visualize the convoluted design of microchannels. ( B ) A 3D layout of a PMI Chip and a zoom-in cross-sectional view illustrate the structural configuration of the convoluted microchannel that contains an organoid-derived 3D epithelial layer. The upper (blue) and lower (red) microchannels mimic the lumen and capillary compartments in the gut, respectively. ( C ) The cross-sectional micrographs of a PMI Chip (upper panel) and the zoom-in insets (lower panel) that highlight the white dashed boxes in the upper panel. An inset in the lower right panel shows a cross-cut view of a PDMS porous membrane (Bar, 50 μm). V, vacuum chamber; U, upper microchannel; L, lower microchannel. ( D ) The velocity profiles of fluid flow (unit, μm/s) in the upper and lower microchannels at 50 μL/h. White arrows in the zoom-in insets indicate the direction of the fluid flow and the magnitude of a linear flow rate.

Article Snippet: A 3D model of a convoluted PMI Chip was created by AutoCAD (Autodesk, San Rafael, CA, USA) and exported into COMSOL Multiphysics 5.4 (COMSOL Inc., Stockholm, Sweden) to estimate fluid hydrodynamics in terms of flow velocity and fluid shear stress.

Techniques: Derivative Assay, Membrane

The microfluidic culture of the patient-derived organoid epithelium in a PMI Chip. ( A ) The phase contrast micrographs of human intestinal organoids derived from a normal donor or the patients diagnosed with UC, CD, and CRC. ( B ) The experimental procedure for the activation of a microfluidic channel and a subsequent ECM coating in a PMI Chip. ( C ) The procedure of the formation of biopsy-derived intestinal organoids and its use for a microfluidic culture in a PMI Chip. ( D ) The phase contrast images that show the 3D regeneration of patient-derived intestinal organoid epithelium under non-linear luminal flow and multiaxial stretching motions. Normal organoid cells were cultured in a PMI Chip for 7 days under flow (50 µL/h) and stretching motions (5%, 0.15 Hz). Bars, 200 μm.

Journal: Micromachines

Article Title: Three-Dimensional Regeneration of Patient-Derived Intestinal Organoid Epithelium in a Physiodynamic Mucosal Interface-on-a-Chip

doi: 10.3390/mi11070663

Figure Lengend Snippet: The microfluidic culture of the patient-derived organoid epithelium in a PMI Chip. ( A ) The phase contrast micrographs of human intestinal organoids derived from a normal donor or the patients diagnosed with UC, CD, and CRC. ( B ) The experimental procedure for the activation of a microfluidic channel and a subsequent ECM coating in a PMI Chip. ( C ) The procedure of the formation of biopsy-derived intestinal organoids and its use for a microfluidic culture in a PMI Chip. ( D ) The phase contrast images that show the 3D regeneration of patient-derived intestinal organoid epithelium under non-linear luminal flow and multiaxial stretching motions. Normal organoid cells were cultured in a PMI Chip for 7 days under flow (50 µL/h) and stretching motions (5%, 0.15 Hz). Bars, 200 μm.

Article Snippet: A 3D model of a convoluted PMI Chip was created by AutoCAD (Autodesk, San Rafael, CA, USA) and exported into COMSOL Multiphysics 5.4 (COMSOL Inc., Stockholm, Sweden) to estimate fluid hydrodynamics in terms of flow velocity and fluid shear stress.

Techniques: Derivative Assay, Activation Assay, Cell Culture

The regeneration of 3D epithelial morphology in a PMI Chip. The DIC micrographs reveal the 3D morphogenesis when the intestinal organoids obtained from normal ( A ) or various patient donors with UC ( B ), CD ( C ), CRC ( D ) as well as a Caco-2 epithelium ( E ) are cultured in a PMI Chip for approximately 150 h under dynamic flow (50 µL/h) and motions (5%, 0.15 Hz). A right inset in “A” is a zoomed-in view of the area indicated by a white dashed box. Bars, 100 μm. ( F ) The height of organoid-derived or Caco-2 intestinal epithelium cultured in a PMI Chip after 150 h. * p < 0.05, *** p < 0.001. NS, not significant.

Journal: Micromachines

Article Title: Three-Dimensional Regeneration of Patient-Derived Intestinal Organoid Epithelium in a Physiodynamic Mucosal Interface-on-a-Chip

doi: 10.3390/mi11070663

Figure Lengend Snippet: The regeneration of 3D epithelial morphology in a PMI Chip. The DIC micrographs reveal the 3D morphogenesis when the intestinal organoids obtained from normal ( A ) or various patient donors with UC ( B ), CD ( C ), CRC ( D ) as well as a Caco-2 epithelium ( E ) are cultured in a PMI Chip for approximately 150 h under dynamic flow (50 µL/h) and motions (5%, 0.15 Hz). A right inset in “A” is a zoomed-in view of the area indicated by a white dashed box. Bars, 100 μm. ( F ) The height of organoid-derived or Caco-2 intestinal epithelium cultured in a PMI Chip after 150 h. * p < 0.05, *** p < 0.001. NS, not significant.

Article Snippet: A 3D model of a convoluted PMI Chip was created by AutoCAD (Autodesk, San Rafael, CA, USA) and exported into COMSOL Multiphysics 5.4 (COMSOL Inc., Stockholm, Sweden) to estimate fluid hydrodynamics in terms of flow velocity and fluid shear stress.

Techniques: Cell Culture, Derivative Assay

The characterization of the 3D morphology and differentiation of patient-derived organoid epithelium grown in a PMI Chip. The angled views of the 3D epithelial layer derived from ( A , B ) normal, ( C ) CD, ( D ) UC, and ( E ) CRC organoids. The insets in the figures from A to E displays the vertical cross-cut view of each 3D epithelial layer. Various structural (F-actin, E-cadherin), functional (MUC2, Ki-67), or disease-specific markers (CEA, CD133) were highlighted by immunofluorescence staining followed by confocal microscopy. As a counterstaining, nuclei were highlighted in cyan. Bars, 100 μm. The quantitative comparisons of the expression of functional (MUC2) ( F ) and disease-specific markers (CEA, CD133) ( G ) in the normal and the patient-derived organoid epithelium in a PMI Chip. ** p < 0.01, *** p < 0.001.

Journal: Micromachines

Article Title: Three-Dimensional Regeneration of Patient-Derived Intestinal Organoid Epithelium in a Physiodynamic Mucosal Interface-on-a-Chip

doi: 10.3390/mi11070663

Figure Lengend Snippet: The characterization of the 3D morphology and differentiation of patient-derived organoid epithelium grown in a PMI Chip. The angled views of the 3D epithelial layer derived from ( A , B ) normal, ( C ) CD, ( D ) UC, and ( E ) CRC organoids. The insets in the figures from A to E displays the vertical cross-cut view of each 3D epithelial layer. Various structural (F-actin, E-cadherin), functional (MUC2, Ki-67), or disease-specific markers (CEA, CD133) were highlighted by immunofluorescence staining followed by confocal microscopy. As a counterstaining, nuclei were highlighted in cyan. Bars, 100 μm. The quantitative comparisons of the expression of functional (MUC2) ( F ) and disease-specific markers (CEA, CD133) ( G ) in the normal and the patient-derived organoid epithelium in a PMI Chip. ** p < 0.01, *** p < 0.001.

Article Snippet: A 3D model of a convoluted PMI Chip was created by AutoCAD (Autodesk, San Rafael, CA, USA) and exported into COMSOL Multiphysics 5.4 (COMSOL Inc., Stockholm, Sweden) to estimate fluid hydrodynamics in terms of flow velocity and fluid shear stress.

Techniques: Derivative Assay, Functional Assay, Immunofluorescence, Staining, Confocal Microscopy, Expressing

The co-culture of the fecal microbiome in a PMI Chip lined by 3D intestinal epithelium under an AOI. ( A ) The overlaid images of a DIC and a fluorescent micrograph show the snapshot of a host–microbiome co-culture in the PMI Chip. The human fecal microbiome (initial seeding density, 5 × 10 4 cells/mL) was co-cultured with the germ-free Caco-2 intestinal epithelium in a PMI Chip under luminal flow (100 µL/h) and multiaxial stretching motions (5% in cell strain, 0.15 Hz in frequency) for 2 days. The AOI was pre-established by perfusing an antibiotic-free anoxic and oxic culture medium in the upper and lower microchannel, respectively for 12 h. The fecal bacteria that formed microcolonies were visualized using Live/Dead staining dye in the lumen microchannel. We performed the same staining into the germ-free PMI Chip (Control). An inset in the “Co-culture” shows the viability of the isolated human fecal microbiome acquired by confocal microscopy. ( B ) The epithelial barrier function was maintained (> 3 kΩ·cm 2 ) regardless of the AOI or the co-culture with the fecal microbiome. The barrier function was assessed by normalizing TEER values. Bar, 50 µm. NS, not significant.

Journal: Micromachines

Article Title: Three-Dimensional Regeneration of Patient-Derived Intestinal Organoid Epithelium in a Physiodynamic Mucosal Interface-on-a-Chip

doi: 10.3390/mi11070663

Figure Lengend Snippet: The co-culture of the fecal microbiome in a PMI Chip lined by 3D intestinal epithelium under an AOI. ( A ) The overlaid images of a DIC and a fluorescent micrograph show the snapshot of a host–microbiome co-culture in the PMI Chip. The human fecal microbiome (initial seeding density, 5 × 10 4 cells/mL) was co-cultured with the germ-free Caco-2 intestinal epithelium in a PMI Chip under luminal flow (100 µL/h) and multiaxial stretching motions (5% in cell strain, 0.15 Hz in frequency) for 2 days. The AOI was pre-established by perfusing an antibiotic-free anoxic and oxic culture medium in the upper and lower microchannel, respectively for 12 h. The fecal bacteria that formed microcolonies were visualized using Live/Dead staining dye in the lumen microchannel. We performed the same staining into the germ-free PMI Chip (Control). An inset in the “Co-culture” shows the viability of the isolated human fecal microbiome acquired by confocal microscopy. ( B ) The epithelial barrier function was maintained (> 3 kΩ·cm 2 ) regardless of the AOI or the co-culture with the fecal microbiome. The barrier function was assessed by normalizing TEER values. Bar, 50 µm. NS, not significant.

Article Snippet: A 3D model of a convoluted PMI Chip was created by AutoCAD (Autodesk, San Rafael, CA, USA) and exported into COMSOL Multiphysics 5.4 (COMSOL Inc., Stockholm, Sweden) to estimate fluid hydrodynamics in terms of flow velocity and fluid shear stress.

Techniques: Co-Culture Assay, Cell Culture, Bacteria, Staining, Control, Isolation, Confocal Microscopy