Review





Similar Products

90
Thermo Fisher liquid chromatography-tandem mass-spectrometry (lc-ms/ms
Liquid Chromatography Tandem Mass Spectrometry (Lc Ms/Ms, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/nct06380387-31-10-23
Average 90 stars, based on 1 article reviews
liquid chromatography-tandem mass-spectrometry (lc-ms/ms - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

99
YMC America liquid chromatography mass spectrometry lc ms
Reaction schemes <t>and</t> <t>LC-MS</t> analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.
Liquid Chromatography Mass Spectrometry Lc Ms, supplied by YMC America, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/YMC-Triart+C18/pmc13123502-92-0-8
Average 99 stars, based on 1 article reviews
liquid chromatography mass spectrometry lc ms - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

95
Agilent technologies 1260 infinity ii lc ms system

1260 Infinity Ii Lc Ms System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/Bio+LC/pmc13771759-74-0-6
Average 95 stars, based on 1 article reviews
1260 infinity ii lc ms system - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Agilent technologies lc ms

Lc Ms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/Bio+LC/pmc13749058-213-5-8
Average 95 stars, based on 1 article reviews
lc ms - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

95
Agilent technologies liquid chromatography ms

Liquid Chromatography Ms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/Bio+LC/pm42971099-80-6-10
Average 95 stars, based on 1 article reviews
liquid chromatography ms - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

98
Danaher Inc lc ms ms

Lc Ms Ms, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/SCIEX+Triple+Quad+6500%2B+System/pm43003571-100-5-9
Average 98 stars, based on 1 article reviews
lc ms ms - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

96
Danaher Inc sciex triple quad 4500

Sciex Triple Quad 4500, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/SCIEX+Triple+Quad+4500+LC-MS%2FMS+System/pmc13748688-244-6-6
Average 96 stars, based on 1 article reviews
sciex triple quad 4500 - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

98
Agilent technologies 6530 accurate mass q tof lc ms

6530 Accurate Mass Q Tof Lc Ms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/PLRP-S/pmc13746262-131-8-12
Average 98 stars, based on 1 article reviews
6530 accurate mass q tof lc ms - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

95
Agilent technologies lc ms analyses

Lc Ms Analyses, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/Bio+LC/pmc13744403-99-1-4
Average 95 stars, based on 1 article reviews
lc ms analyses - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

96
Danaher Inc triple quad 4500 mass spectrometer

Triple Quad 4500 Mass Spectrometer, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/lc+ms/SCIEX+Triple+Quad+4500+LC-MS%2FMS+System/pm42879897-46-19-18
Average 96 stars, based on 1 article reviews
triple quad 4500 mass spectrometer - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results


Reaction schemes and LC-MS analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.

Journal: Synthetic and Systems Biotechnology

Article Title: Functional characterization of four glycosyltransferases for biosynthesis of steroidal saponins in medicinal plant Paris polyphylla

doi: 10.1016/j.synbio.2026.04.002

Figure Lengend Snippet: Reaction schemes and LC-MS analysis of Pp UGTs reactions with diosgenin and pennogenin . ( a ) Biosynthesis of trillin mediated by UGT91BP2 and UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of diosgenin. ( b ) Extracted ion chromatograms (EICs) of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and diosgenin showing the formation of trillin, as compared to the authentic trillin standard. Control is the empty expression vector. ( c ) MS spectra of the enzymatic reaction products in hydrogen and sodium ion adducts compared to the fragmentation pattern of the trillin standard. The product molecular ions [M + H] + and [M +Na] + and the feature fragment ion [M + H − Glc] + with m / z 415.32 are marked. Of note, additional peaks observed in the diosgenin EIC ( m / z 415.32) for UGT703R1–3 might correspond to substrate isomeric impurities, in-source adducts, or minor non-enzymatic by-products; these peaks, which arose from the extracted ion flow of the substrate m / z , did not co-elute with the product, trillin , and therefore did not affect the interpretation of the product formation. ( d ) Biosynthesis of pennogenin 3- O -glucoside mediated by the UGT703R1–3 through transferring glucose from UDP-glucose to the C-3 OH position of pennogenin. ( e ) EICs of the in vitro enzyme activity assays of recombinant UGT91BP2 and UGT703R1–3 with UDP-glucose and pennogenin showing the formation of pennogenin 3- O -glucoside, compared to the control empty expression vector. ( f ) MS/MS spectra ([M + H – Glc] + and [M + H – Glc − H 2 O] + ) of the enzymatic reaction products.

Article Snippet: Liquid chromatography-mass spectrometry (LC-MS) was equipped with a YMC-Triart C18 column (250 mm × 4.6 mm, 5 μm), and the column temperature was set to 30 °C.

Techniques: Liquid Chromatography with Mass Spectroscopy, Transferring, In Vitro, Activity Assay, Recombinant, Control, Expressing, Plasmid Preparation, Tandem Mass Spectroscopy

Journal: iScience

Article Title: Guanidinium-driven fluorescence detection of microcystins using carbon dot embedded silica nanoparticles

doi: 10.1016/j.isci.2026.118193

Figure Lengend Snippet:

Article Snippet: 1260 Infinity II LC-MS System , Agilent Technologies , Model: 1260 Infinity II.

Techniques: